Dc Supply Failure - Motorola APX 1000 Detailed Service Manual

Hide thumbs Also See for APX 1000:
Table of Contents

Advertisement

Troubleshooting Charts: DC Supply Failure
5.4

DC Supply Failure

DC Supply 5 Volt Failure
Replace Fuse
Verify L200, C202
and C203 is good
No
Is fuse intact
(not blown)?
Yes
Verify UNSW_B+ at
No
test point: F_UNSW_B+
Verify Q6501
V_SW_5
No
Is radio current
>100mA
Yes
Verify if USB accessory is
shorting VBUS line.
No
No
Verify SW_B+
at C6565
Is 6 < V < 9
Yes
Measure BGAP_COMP
voltage at R6543
Is 2.2 < V < 2.7
No
Check BGAP_COMP circuitry.
Replace defective part
Yes
Replace accessory
or cable
No
Check Q6502 and
Q6508 for damage
Yes
Check U6505 circuitry. If good,
change U6505