Motorola APX 1000 Detailed Service Manual page 112

Hide thumbs Also See for APX 1000:
Table of Contents

Advertisement

5-14
Power-Up Failure – Low V_EXT_1.85 Voltage
Low V_ENT_1.85 Voltage
Measure Radio
Current
Is standy
current > 15mA
above avg?
No
Measure
V_SW_3.6
Voltage at R6510
Voltage =
V_SW_3.6
Yes
Measure Voltage
R6431 on V_5.0A
Side
4.8 < V < 5.2
No
Proceed to Low
LD08 V_5.0A
Voltage Flow
Chart
Board has a short,
Yes
replace board
Proceed to
No
Incorrect
V_SW_3.6
Voltage
Measure Voltage
Yes
at R6431 on
BGAP_COMP
side
Troubleshooting Charts: Power-Up Failure
Measure Voltage
2.2 < V < 2.7?
at R6420
No
Replace Main
Board
2.2 < V < 2.7?
Yes
Inspect U6508 and
All Supporting
Circuitry
Replace Main Board
Inspect and repair
Yes
U6409 and
Supporting
Circuitry
No
Are Parts Solder
No
Replace or repair
Connections &
Parts
Placement Correct

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Apx 2000Apx 4000liApx 4000

Table of Contents