Fax Communication Error Codes (Al-2060 Only); Error Code Identification - Sharp AL-2020 Service Manual

Digital multifunctional system
Hide thumbs Also See for AL-2020:
Table of Contents

Advertisement

6. FAX communication error codes
(AL-2060 only)
A. Error code identification
Communication error xx (xxxx)
(In print out, the communication error display is made. In FAX status
check, "NGxxxxxx" is displayed.
When transmission or reception is not executed normally due to dis-
tur-bance in protocol signals and image signals by the trouble in the
line, the code of 6 digits is displayed on the transmission result
check menu (reception result check menu).
Upper 2 digits of a communication error code: 00 – 58 (error code)
is displayed. (Communication result code)
Lower 4 digits of a communication error code: Error code 1, Error
code 2
1) Refer to the communication result code.
2) Refer to error code 1.
3) Refer to error code 2.
(Error code 1 other than V.34 mode is "00".)
<Communication result code>
Error code
Communication
(Communication
report result
result)
column
0 – 31
For details of 0 –
31, refer to the
communication
result code.
33
Busy
34
Cancel
35
Power OFF
36
(Recording paper
empty)
37
(Recording paper
jam)
38
Reception
memory over
39
(Discrepancy in
the number of
sheets)
40
(Interface not
accepted)
41
Transmission
length over
42
Reception length
over
43
Communication
(OK)
44
Document error
45
(Image quality
error)
Communication interruption
content
Depends on the
communication
disconnection position.
For 16 or later, V.34 mode
communication.
The calling side cannot
connect the line with the
other party.
An interruption command is
made during transmission or
reception.
A reservation is canceled.
An interruption command is
entered with the interruption
key.
Power OFF during
transmission or reception
Memory over during
reception
The length of transmission
data of one page exceeds
the range during
transmission.
The length of reception data
of one page exceeds the
range during reception.
Communication enable
before transmission
A document jam during
direct transmission
AL-2020/2035/2040/2050/2060 SIMULATION, TROUBLE CODES 10 - 43
Error code
Communication
(Communication
report result
result)
column
46
No response from
the other party
47
(Communication
error)
48
OK
49
No send request
function on the
other party
50
Send request not
accepted
51
Send request
enable number
discrepancy
52
No confidential
function on the
other party
53
Confidential
function not
accepted
54
Confidential box
No. NG
55
No interface
function on the
other party
56
Interface not
accepted
57
Interface ID
discrepancy
58
Reception
inhibition number
Communication interruption
content
The FAX signal from the
other party cannot detect
within T1 time.
Communication normal end
The other party has no send
request function when
receiving a send request.
The other party has no data
to send.
DCN is received for DTC
when sending a send
request.
There is no data to send
when sending a send
request.
Discrepancy in the enable
number when sending a
send request.
Discrepancy in the system
number when sending a
send request.
The other party has no
confidential function when
sending a confidential
message. (Including the
other company's machines)
DCN is received for NSS
when receiving a confidential
message.
A confidential box number
which is not registered is
directed when receiving a
confidential message.
The other party has no
interface function when
sending an interface
command.
DCN is received for NSS
when sending an interface
command.
A receiving station number
which is not registered is
directed when receiving an
interface command.
Discrepancy in the interface
ID when receiving an
interface command.
Transmission is made from a
reception inhibition number.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Al-2050Al-2060Al-2035Al-2040

Table of Contents