Simulation, Trouble Codes; Entering The Simulation Mode; Key Rule; List Of Simulations - Sharp AL-2020 Service Manual

Digital multifunctional system
Hide thumbs Also See for AL-2020:
Table of Contents

Advertisement

[10] SIMULATION, TROUBLE CODES

1. Entering the simulation mode

To enter the serviceman simulation mode, press the keys as fol-
lows:
AL-2020/2035/2040
[Clear] key
Exposure mode selector key
Exposure mode selector key
AL-2050/2060
[#] key
[
] key
[Clear] key
To cancel the simulation mode, press the [Clear All] key.

2. Key rule

AL-2020/2035/2040
[ ] [ ] key:
Entry of MAIN CODE/SUB CODE
Setting of the adjustment values for the
adjustment-related simulations
When [%] key is pressed simultaneously, the
value is displayed in the descending sequence
such as [0]
[START] key:
Settlement
<In case of simulations for print>
[START] key: Settlement / Print
[Exposure mode
selector] key:
Selection of an item
[Clear] key:
(Interrupting operation check) Returns to the
upper hierarchy.
On the initial display (00-00), it terminates the
simulation.
Exits from the simulation mode.
For a simulation of adjustment, the display
returns to the initial display (00-00).
AL-2050/2060
[Numeric] key:
Entry of MAIN CODE/SUB CODE
Selection of an item
Setup of an adjustment value in case of
simulations for adjustment
[
] [
] key:
Selection of MAIN CODE/SUB CODE
Selection of an item
[OK]/[START] key: Settlement
<In case of simulations for print>
[OK] key: Settlement (Without print)
[START] key: Settlement / Print
[Clear] key:
(Interrupting operation check) Returns to the
upper hierarchy.
In case of simulation of operation check,
terminates the operations.
[Clear All] key:
Exits from the simulation mode.
For a simulation of adjustment, the display
returns to the initial display (00-00).

3. List of simulations

Sim
Sub
No.
code
01
01
Mirror scan operation
02
Mirror home position sensor (MHPS) status display
06
Aging of mirror scanning
02
01
SPF/RSPF aging operation (excluding AL-2020)
02
SPF/RSPF sensor status display
(excluding AL-2020)
03
SPF/RSPF Motor ON (excluding AL-2020)
06
Resist clutch ON (SPF) (AL-2035/2040)
[Clear] key
[
] key
[9], not as [0]
[1].
Operation
AL-2020/2035/2040/2050/2060 SIMULATION, TROUBLE CODES 10 - 1
Sim
Sub
No.
code
02
08
RSPF paper feed solenoid operation check
(AL-2050/2060)
09
RSPF reverse solenoid operation check
(AL-2050/2060)
03
03
Shifter operation check (AL-2050/2060)
05
01
Operation panel display check
02
Fusing lamp, cooling fan operation check
03
Copy lamp ON
06
01
Paper feed solenoid ON
02
Resist solenoid ON
07
01
Warm-up display and aging with jam
06
Intermittent aging
08
Shift to copy with the warm-up display
08
01
Developing bias
02
Main charger (Grid high)
03
Grid voltage (Low)
06
Transfer charger
09
01
Duplex motor normal rotation operation check
02
Duplex motor reverse operation check
04
Duplex motor rotation speed adjustment
10
Toner motor aging
14
Cancel of troubles other than U2
16
Cancel of U2 trouble
22
04
JAM total counter display
05
Total counter display
08
SPF/RSPF counter display (excluding AL-2020)
11
FAX-related counter display (AL-2060 only)
12
Drum counter display
14
ROM version display
16
Duplex counter display
17
Copy counter display
18
Printer counter display
19
Scanner mode counter display
21
Scanner counter display
22
SPF/RSPF JAM counter display
(excluding AL-2020)
24
01
JAM total counter clear
04
SPF/RSPF counter clear (excluding AL-2020)
05
Duplex counter clear
07
Drum counter clear
08
Copy counter clear
09
Printer counter clear
10
FAX counter clear (AL-2060 only)
13
Scanner counter clear
14
SPF/RSPF JAM total counter clear
(excluding AL-2020)
15
Scanner mode counter clear
25
01
Main motor operation check
(Cooling fan motor rotation check)
10
Polygon motor ON
26
02
SPF/RSPF setup (excluding AL-2020)
04
Machine duplex setup
06
Destination setup
07
Machine conditions check
20
Rear edge void setup
30
CE mark support control ON/OFF
38
Cancel of stop at drum life over
39
Memory capacity check
40
Polygon motor OFF time setup (Time required for
turning OFF after completion of printing)
42
Transfer ON timing control setup
43
Side void setup
γ
54
life correction setting
62
Energy-save mode copy lamp setup
Operation

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Al-2050Al-2060Al-2035Al-2040

Table of Contents