2) Clean the TC front guide and the TC holder with alcohol.
3) Set the charger cleaner to the transfer unit, and move it recipro-
cally a few times in the direction of the arrow shown in the figure
below.
3)
E. Charger wire replacement
1) Remove the TC cover and remove the screw.
2) Remove the spring and remove the charger wire.
3) Install a new charger wire by reversing the procedures (1) and
(2).
At that time, be careful of the following items.
• The rest of the charger wire must be within 1.5mm. Refer to Fig.1
• The spring hook section (charger wire winding section) must be
in the range of the projection section.
• Be careful not to twist the charger wire.
4)
2)
1)
AL-2030/2040CS/2050CS
1)
Charger wire
Protrusion

2. Operation panel section

A. List
No.
Part name Ref.
1
Operation panel unit
2
Operation PWB
B. Disassembly procedure
1) Open the side door, and Open the front cover.
2)
DISASSEMBLY AND ASSEMBLY 8 - 2
3)
2)
1mm
1.5mm
Fig.1
1)
1)