Finalizing the Installation
7
Turn the flame adjust knob to its highest position - the flames should be approximately 12" tall. Check
the flame on low position. The flames should burn off of each burner hole. If the heater does not work
correctly, contact your dealer for a remedy.
8
Install the faceplate.
!
ACID WASH WARNING : Before installing the faceplate, make sure any masonry that has been
treated with acid wash has been properly neutralized (this is used primarily with brick faces). Acid wash
(muriatic acid) is used to remove excess mortar. If not properly neutralized with an ammonia solution,
the gold face may develop a permanent tarnish when the acid evaporates over time. Contact your
dealer if uncertain your facing has been properly neutralized.
9
Give this manual to the home owner and fully explain the operation of this heater.