1 1 Remove the regulator from the front of the gas control valve. Replace with the propane regulator,
using the new gasket and screws included with the regulator. NOTE: Leak test this area after
the heater is installed, gas is connected, and the main burner is lit.
NOTE: These holes strip
Align the regulator
easily. Use a hand
gasket so it is flat
screwdriver and tighten
and the two tabs fit
each screw evenly.
through the two
holes on the
gasket.
PILOT ADJ
1 2 Place the included propane label over the natural gas
label on top of the gas control valve.
1 3 Make the gas line connection, start the heater and thoroughly leak-test all gas connections and the
regulator. Check the pilot. Adjust if necessary.
To adjust the pilot
flame, remove the
cover screw and
gasket and turn the
needle valve (NOTE:
if the needle valve is
totally unscrewed,
gas will come out of
this port). Clockwise
lowers the flame
while counter-
clockwise raises it.
Replace the cover
screw and gasket
Cover Screw Gasket
1 4 Inspect the flames. Adjust the air shutter if necessary (see step 7 on page 34).
Travis Industries
Regulator Gasket
NOTE: use the new gasket
included with the regulator.
Needle Valve
Micro (1/16Ó)
Standard
PILOT ADJ
Screwdriver
Cover Screw
Standard
Screwdriver
9 3 5 0 8 1 0 9
(for qualified installers only)
These screws hold the
regulator in place.
NOTE: use the new
screws included with
the regulator.
Phillips
Screwdriver
LP (propane) regulators have a
11.0 2.7 stamped here.
The pilot flame should touch only the top 3/8Ó of the
thermopile. Adjust the pilot up or down as necessary.
Thermopile
Pilot Hood
3/8Ó
4 9
THIS CONTROL
HAS BEEN
CONVERTED TO
LP
Thermocouple
1 8 0 5 0 1