WIRING INSTRUCTIONS

Warning:
All wiring should be done by a qualified electrician and shall be in compliance with local
codes and with the current National Electric Code ANSI/NFPA 70 (in the U.S.), or with the
current CSC22.1 Canadian Electric Code (in Canada).
Warning:
Make sure the fireplace electrical circuit is disabled prior to working on electrical hookup.
Wiring Diagram
Fireplace
Hot
Hot
(black)
(black)
Common
Common
Connector
(white)
(white)
Ground
Ground
(green)
(green)
Fireplace
Blower
Travis Industries
Grill
Blower
Snap Disk
Molex
Fireplace
Rheostat
9 3 5 0 8 1 0 9
(for qualified installers only)
Wall Adapter
(for use when the blower box
protrudes from the wall -
primarily on 2 x 4 walls)
Hot
(black)
Molex
Common
Common
Connector
(white)
Ground
(green)
Common
Heat Duct
Rheostat
Hot
Hot
(black)
(black)
Common
(white)
(white)
Ground
Ground
(green)
(green)
Rheostat
Junction
Box
Hot
(black)
Optional Second Heat
Duct (same rheostat and
(white)
blower wiring as above)
Ground
(green)
5 3
Heat Duct
Blower
Hot
(black)
Common
(white)
Ground
(green)
Blower
Junction
Box
Grounded
to Blower