1.3
Airflow Direction Control
Power-Airflow
The large flap sends a large volume of air downward to the floor and provides an optimum control in
cooling, dry, and heating operation.
(Dual) Flap (s)
Cooling/Dry
During cooling or dry operation, the flap retracts into the indoor unit. Then, cool air can be blown far
and distributed all over the room.
Heating
During heating operation, the large flap directs airflow downward to spread the warm air to the
entire room.
Wide-Angle
The louvers, made of elastic synthetic resin, provide a wide range of airflow that guarantees
comfortable air distribution.
Louvers
Auto-Swing
The following tables explain the auto-swing process for cooling, dry, heating, and fan:
FTX Series
FVXS Series
airflow limit
airflow limit
Functions and Control
Cooling/Dry
5˚
09/12 class
50˚
15˚
15 class
55˚
Flap (up and down)
Cooling/Dry
Upward
OFF
(R6831)
Upward
ON
(R6832)
Flap (up and down)
Heating
15˚
65˚
(R21049)
(R21048)
20˚
30˚
35˚
70˚
65˚
(R21652)
(R21651)
Heating
(R6829)
(R6830)
Fan
0˚
65˚
(R21050)
10˚
25˚
80˚
80˚
65˚
(R21653)
Main Functions
22