Daikin FTX09NMVJU Service Manual page 35

Hide thumbs Also See for FTX09NMVJU:
Table of Contents

Advertisement

SiUS091601E
When setting the airflow selection switch to
Operating mode
• During dry operation, air is blown upper air outlet, so that cold air does not come into direct
When setting the airflow selection switch to
Functions and Control
Air conditioner automatically decides the appropriate blowing pattern depending on the
operating mode/situation.
When the operation is activated or
when the room is not fully cooled.
Cooling
When the room has become fully
cool, or when 1 hour has passed
since turning on the air
conditioner.
When the operation is activated or
when air emitted is of low
temperature.
Heating
At times other than the above
situations.
Whenever in DRY mode.
Dry
Whenever in FAN mode.
Fan
Operates in the actual operation mode of the air conditioner according to the
Automatic
descriptions in this table. (COOL or HEAT)
contact with people.
Regardless of the operating mode or situation, air is blown from the upper air outlet.
Use this switch when you do not want air coming out of the lower air outlet (e.g., while sleeping).
.
Situation
.
Main Functions
Blowing pattern
Air is blown from the upper and
lower air outlets in order to reach
the set temperature quickly.
Air is blown only from the upper air
outlet so that air does not come into
direct contact with people and
indoor temperature is equalized.
Air is blown only from the upper air
outlet so that air does not come into
direct contact with people.
Air is blown from the upper and
lower air outlets so that warm air is
spread throughout the whole room.
Air is blown only from the upper air
outlet so that air does not come into
direct contact with people.
24