6. Replace burner base and hand tighten the screws.
7. Replace burner cap.
8. Repeat steps 1 through 7 for the remaining burners.
9. Place Natural gas orifice spuds in plastic parts bag for future
use and keep with package containing literature.
10. Replace burner grates.
11. Complete installation. See "Make Gas Connection" and
"Electronic Ignition System" sections.
Checking for proper cooktop burner flame is very important.
The small inner cone should have a very distinct blue flame ¼"
to ½" long. The outer cone is not as distinct as the inner cone.
LP gas flames have a slightly yellow tip.
IMPORTANT: You may have to adjust the "LO" setting for
each cooktop burner.

Natural Gas Conversion

WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
1. Turn manual shutoff valve to the closed position.
2. Unplug range or disconnect power.
A
A. To range
B. Shutoff valve (closed position)
C. Gas supply line
To Convert Gas Pressure Regulator
3. Locate gas pressure regulator at the back of the range.
IMPORTANT: Do not remove the gas pressure regulator.
4. Unscrew the regulator cap and remove the plastic cover.
5. Flip the regulator cap over and replace the plastic cover.
B
C
6. Screw the regulator cap securely back into place. Do not
overtighten.
A. Plastic cover
B. Regulator cap
B
A
A. LP gas position
B. Natural gas position
C. Plastic cover
2
A
B
C
15