Features and specifications

Microprocessor:
Intel® Pentium® III Xeon™
32 KB of level-1 cache
1 MB of level-2 cache (minimum)
Expandable to four
microprocessors
Memory:
Maximum: 16 GB
Type: ECC, SDRAM, Registered
DIMMs
Slots: 4-way interleaved, 16 slots
Drives standard:
Diskette: 1.44 MB
CD-ROM: IDE
Expansion bays:
Hot-swap: 10 slim-high
Non-hot-swap: Two 5.25-inch
LVD SCSI Backplane:
Ultra160 capable
Two SCSI channels, each with
five connectors, in a split
configuration
Supports a maximum of 10 slim-
high hard disk drives
PCI expansion slots:
Four 33 MHz 64-bit hot-plug
Two 66 MHz 64-bit non-hot-plug
Hot-swap power supplies:
250 Watt (115-230 V ac)
Minimum: Two
Maximum: Four
Three for redundancy
Redundant cooling:
Four hot-swap fan assemblies
2
IBM® xSeries 250: Installation Guide
The following table provides a summary of the features and specifications for your
xSeries 250 server.
Video:
S3 video controller
Compatible with SVGA and VGA
4 MB video memory
Size:
Height: 356 mm (14 in.)
Depth: 650 mm (25.6 in.)
Width: 440 mm (17.3 in.)
Weight: 34.4 kg (76 lb.) to 61 kg
(134 lb.) depending upon
configuration
Integrated functions:
Advanced System Management
processor
Dual Ultra2 (LVD) SCSI
controller, one external port, one
internal port
One 10BASE-T/100BASE-TX
AMD Ethernet controller
Two serial ports
One parallel port
Two Universal Serial Bus ports
Keyboard port
Mouse port
Video port
One management port
Two Advanced System
Management Interconnect ports
Acoustical noise emissions:
Sound power, idle: 6.3 bel
maximum
Sound power, operating: 6.3 bel
maximum
Sound pressure, idle: 49 dBa
maximum
Sound pressure, operating: 49
dBa maximum
Table 1. Features and specifications.
Environment:
Air temperature:
— Server on: 10º to 35º C (50º to
95º F). Altitude: 0 to 914 m
(3000 ft.)
— Server on: 10º to 32º C (50º to
89.6º F). Altitude: 914 m
(3000 ft.) to 2133 m (7000 ft.)
— Server off: 10º to 43º C (50º to
110º F). Maximum altitude:
2133 m (7000 ft.)
Humidity:
— Server on: 8% to 80%
— Server off: 8% to 80%
Heat output:
Approximate heat output in British
Thermal Units (BTU) per hour
Minimum configuration: 1023.9
BTU
Maximum configuration: 2764.6
BTU
Electrical input:
Sine-wave input (50-60 Hz)
required
Input voltage low range:
— Minimum: 90 V ac
— Maximum: 137 V ac
Input voltage high range:
— Minimum: 180 V ac
— Maximum: 265 V ac
Input kilovolt-amperes (kVA)
approximately:
— Minimum: 0.08 kVA
— Maximum: 0.52 kVA