Step 4. Field Wiring - Superior DRT63STTEN Installation And Operation Instructions Manual

Drt63st see-through direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
DRT63ST Direct-Vent Gas Fireplaces

Step 4. FIELD WIRING

CAUTION: Label all wires prior to discon-
nection when servicing controls. wiring
errors can cause improper and dangerous
operation.
ATTENTION: Au moment de l'entretien
des commandes, étiquetez tous les fils
avant de les débrancher. Des erreurs
de cáblage peu-vent entraîner un fonc-
tionnement inadéquat et dangereux.
Verify proper operation after servicing.
S'assurer que l'appareil fonctionne adé-
quatement une fois l'entretien terminé.
CAUTION
Ground supply lead must be connect-
ed to the wire attached to the green
ground screw located on the outlet
box. See Figures 35 and 36. Failure to
do so will result in a potential safety
hazard. The appliance must be elec-
trically grounded in accordance with
local codes or, in the absence of local
codes, the National Electrical Code,
ANSI/NFPA 70-latest edition.
Junction Box
120V AC
B
W
Hi-Temp Sleeve
Cable Harness 102661-01
Wiring Color Code
B = Black
BR = Brown
BL = Blue
G = Green
Figure 35 - Electronic Wiring Diagram for Gravity Vent Fireplaces
28
Electronic Wiring
(See Figures 35 and 36)
Note: The electronic appliance must be
connected to the main power supply.
1. Route a 3-wire, 120 Vac, 60 Hz, 1ph power
supply to the appliance junction box.
2. Remove the electrical inlet cover plate from
the side of the unit by removing the plate's
securing screws (see Figure 14, Page 17).
3. Remove the cover plate's knockout and then
feed the power supply wire through the
knockout opening and into the unit junction
box.
Figure 36 - Junction Box Wiring
(See Figure 36 for detailed drawing
of junction box / receptacle wiring.)
ELECTRONIC WIRING DIAGRAM FOR GRAVITY VENT FIREPLACES
AC/DC
Power Adaptor
Hot
Neutral
Ground
G
Wall Receiver
GY
R
B
BR
O
Y
W
G
BL
PU
GY = Gray
PU = Purple
R = Red
O= Orange
W = White
Y = Yellow
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Green
White
black
Tab Intact
Tab Intact
Hot
Side of
Green
Neutral
Receptacle
Ground
Side of
Screw
Receptacle
B
BR
Y
O
O
G
Proflame Valve
Y
Electronic Modulation
DFC Wire Harness 102662-01
G
W
THIS CONNECTOR NOT
USED ON GRAVITY
VENT UNITS
Installation Instructions
4. Connect the black power supply wire to the
power outlet's red pigtail lead and the white
power supply wire to the common terminal
of the outlet as shown in Figures 35 and 36.
5. Connect the ground supply wire to the pig-
tail lead attached to outlet's green ground
screw.
6. Appliance-mounted ON/OFF burner control
switch (rocker switch) is factory installed.
7. After wiring is complete, replace the cover
plate.
Ground - Green
Neutral - White
120 VAC - black
Junction Box
J-bOX / RECEPTACLE
Red
WIRING
120V, 60HZ, 1PH
Field Wired
Factory Wired
Electronic Pilot Assembly
Igniter Rod
Hood
B
Pilot
R
Spark Wire Cable
Tube
Y
Pilot
Ground
Wire
Y
G
O
W
W
G
BL
PU
Unit Mounted Rocker Switch
OFF (o) = Intermittent Pilot Mode
ON (-) = Standing Pilot Mode
900355-01, 07/2015
Flame
Sensor
Pilot Sensor Cable
Proflame
DFC Board