Step 5. FIELD WIRING

CAUTION
The ground supply lead must be
connected to the wire attached to
the green ground screw located
on the outlet box (see wiring
diagrams). Failure to do so
will result in a potential safety
hazard. The appliance must be
electrically grounded in accor-
dance with local codes or, in
the absence of local codes, the
National Electrical Code, ANSI/
NFPA 70—latest edition (in
Canada, the current
CSA C22.1
Canadian Electrical Code).
CAUTION: Label all wires prior to discon-
nection when servicing controls. Wiring
errors can cause improper and dangerous
operation.
f i r e - p a r t s . c o m
ATTENTION: Au moment de l'entretien
des commandes, étiquetez tous les
fils avant de les débrancher. Des
erreurs de cáblage peuvent entraîner
un fonctionnement inadéquat et
dangereux.
Verify proper operation after servicing.
S'assurer que l'appareil fonctionne
adéquatement une fois l'entretien
terminé.
• DIRECT-VENT GAS FIREPLACES (SDV35-N-2) • INSTALLATION INSTRUCTIONS
®
APPLIANCE- MOUNTED
ON/OFF SWITCH
(OPTIONAL)
BK/W(1)
BK/W(1)
WALL-MOUNTED ON/OFF SWITCH (OPTIONAL)
THERMOSTAT (OPTIONAL)
Figure 46: Wiring Diagram—
WALL MOUNTED CONFIGURATION FOR FAN SWITCH (OPTIONAL)
Millivolt Gas Valves
FAN
(OPTIONAL)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Refer to Section A for millivolt appliances.
THERMOPILE
The gas valve is set in place and pre-wired at
the factory on both models.
Wiring
TP-TH
TP
TH
This unit is not provided with factory-
installed controls; therefore, one of the
GAS VALVE
optional control switches is required to
operate the unit (ON/OFF Wall Switch, Unit-
Mountable ON/OFF Switch*, Thermostat,
Remote Control). See the fireplace Care and
Operation Instructions for details.
[*If using a Unit-Mountable ON/OFF Rocker
Switch with an optional Style View Door, mount
the Rocker Switch on the door instead of the
unit.]
1. If installing an ON/OFF wall switch or
2. Wire the control switch within the millivolt
BK
R
W
GR
JUNCTION BOX
In millivolt systems, do NOT connect
a Wall Switch to a 120V power supply.
(see Figure 46)
thermostat, mount it in a convenient
location on a wall near the fireplace.
control circuit using the 15 feet of 2
conductor wire supplied with the unit.
Note: The supplied 15 feet of 2 conductor
wire has one end of each conductor
connected to the gas valve circuit and the
other end of each conductor placed loose
inside the bottom compartment.
CAUTION
25