COLD CLIMATE INSULATION

For cold climate installations, seal all cracks
around the appliance with noncombustible
material and wherever cold air could enter the
room. If the floor is above ground level, it is
especially important to insulate outside chase
cavity between studs and under the floor on
which the appliance rests. Gas line holes and
other openings should be caulked or stuffed
with unfaced fiberglass insulation.
If the fireplace is being installed on a cement
slab in cold climates, a sheet of plywood or
other raised platform can be placed under-
neath to prevent cold transfer to the fireplace
and into the room. It also helps to sheetrock
inside surfaces and tape for maximum air
tightness and caulk firestops.
MANUFACTURED HOME
REQUIREMENTS
This appliance may be installed in an aftermar-
ket, permanently located, manufactured home
and must be installed in accordance with the
manufacturer's instructions.
Cet appareil peut être installé cómme
du matéri-el d'origine dans une maison
préfabriquée (É.U. seulement) ou mobile
et doit être installé selon les instructions
du fabricant.
This appliance is only for use with the type
of gas indicated on the rating plate. This ap-
pliance is not convertible for use with other
gases, unless a certified kit is used.
Cet appareil doit être utilisé uniquement
avec le type de gaz indiqué sur la plaque
signalétique. Cet appareil ne peut être con-
verti à d'autres gaz, sauf si une trousse de
conversion est utilisée.
CAUTION: Ensure that the cross members
are not cut or weakened during installation.
The structural integrity of the manufactured
home floor, wall, and ceiling / roof must be
maintained.
CAUTION: This appliance must be grounded
to the chassis of the manufactured home
in accordance with local codes or in the
absence of local codes, with the National
Electrical Code ANSI / NFPA 70 - latest edi-
tion or the Canadian Electrical Code CSA
C22.1 - latest edition.
10
Drywall
Top of Fireplace
Opening
When unit is installed with one side flush with a wall, the wall on
other side of unit must not extend beyond front edge of unit.
Figure 2 - Typical Installation/Locations

LOCATION

In selecting the location, the aesthetic and
functional use of the appliance are primary
concerns; however, vent system routing to the
exterior and access to the fuel supply are also
important.
Due to high temperatures, the appliance
should be located out of traffic and away
from furniture and draperies (Figure 2).
En raison des températures élevées,
l'appareil devrait être installé dans
un endroit où il y a peu de circulation
et loin du mobilier et des tentures
(Figure 2).
The location also should be free of electrical,
plumbing, or other heating/air conditioning
ducting.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
General Information
900355-01, 07/2015
Outdoors
Indoors
(Top View)
Be aware that this is a heat-producing ap-
pliance. Objects placed above the unit are
exposed to elevated temperatures.
Do not insulate the space between the appli-
ance and the area above it.
The appliance must be mounted on a fully
supported base extending the full width and
depth of the unit. The appliance may be lo-
cated on or near conventional construction
materials. However, if installed on combustible
materials, such as carpeting, vinyl tile or other
combustible material other than wood flooring,
the appliance shall be installed on a metal or
wood panel extending the full width and depth
of the appliance.