4-4 Replacing Consumable Parts

Replacing the Separating Knife

If the separating knife becomes dull, replace it with the included replacement knife.
CAUTION
CAUTION
1.
Enter the blade replacement mode.
MENU
SUB MENU
SUB MENU
MAINTENANCE
MAINTENANCE
REPLACE KNIFE
NOW PROCESSING..
OPEN FRONT
FINISHED?
2.
Replace the separating knife.
Positioning
groove
70
Chapter 4 Maintenance and Adjustment
Be sure to perform operations as specified by these instructions, and never touch
any area not specified in the instructions.
Sudden movement of the machine may cause injury.
Never touch the tip of the separating knife with your fingers.
Doing so may result in injury.
Press
Press
Press
Press
Press
Press
Press
The cutting carriage moves to a location where blade replacement is possible, and
then the screen shown in the figure appears.
COVER
Open the front cover.
Preparations are complete when this screen appears.
2
1
Magnet
.
several times.
.
.
.
several times.
.
Remove the separating knife.
1.
Loosen the screw until it slips out.
2.
Grasp the screw portion, and slowly pull it
out in the direction of the arrow. When do-
ing this, do not pull it back toward you.
Install a new knife.
The knife is secured in place by the magnet.