Field Name
Attainable Rate (Kbps)
PhyR Status
Rate (Kbps)
MSGc (# of bytes in overhead channel
message)
B (# of bytes in Mux Data Frame)
M (# of Mux Data Frames in FEC Data Frame) (Path 0/1, Downstream/Upstream)
T (Mux Data Frames over sync bytes)
R (# of check bytes in FEC Data Frame)
S (ratio of FEC over PMD Data Frame length)
L (# of bits in PMD Data Frame)
D (interleaver depth)
Delay (msec)
INP (DMT symbol)
Super Frames
Super Frame Errors
RS Words
RS Correctable Errors
RS Uncorrectable Errors
RS Codewords Received
RS Codewords Corrected
RS Codewords Uncorrected
HEC Errors
OCD Errors
LCD Errors
Total Cells
Data Cells
Bit Errors
Total ES
Total SES
Total UAS
SMARTRG INC. PROPRIETARY AND CONFIDENTIAL. ALL RIGHTS RESERVED. COPYRIGHT © 2014
Description
(Downstream/ Upstream) The typically obtainable sync rate.
[Inactive, Active] Physical Layer Retransmission feature status. (Downstream/ Upstream)
(Path 0/1, Downstream/Upstream) Current sync rate
(Path 0/1, Downstream/Upstream)
(Path 0/1, Downstream/Upstream)
(Path 0/1, Downstream/Upstream)
(Path 0/1, Downstream/Upstream)
(Path 0/1, Downstream/Upstream)
(Path 0/1, Downstream/Upstream)
(Path 0/1, Downstream/Upstream)
(Path 0/1, Downstream/Upstream)
(Path 0/1, Downstream/Upstream)
(Path 0/1, Downstream/Upstream) Total number of super frames.
(Path 0/1, Downstream/Upstream)
Total number of super frames received with errors.
(Path 0/1, Downstream/Upstream)
Total number of Reed-Solomon code errors.
(Path 0/1, Downstream/Upstream)
Total number of Reed-Solomon with correctable errors.
(Path 0/1, Downstream/Upstream)
Total number of Reed-Solomon with uncorrectable errors.
(Path 0/1, Downstream/Upstream)
Total number of Reed-Solomon Codewords received.
(Path 0/1, Downstream/Upstream)
Total number of Reed-Solomon Codewords corrected.
(Path 0/1, Downstream/Upstream) Total number of Reed-Solomon Codewords Uncorrected
(Path 0/1, Downstream/Upstream) Total number of Header Error Checksum errors
(Path 0/1, Downstream/Upstream) Total number of Out-of-Cell Delineation errors
(Path 0/1, Downstream/Upstream) Total number of Loss of Cell Delineation errors
(Path 0/1, Downstream/Upstream) Total number of Cells
(Path 0/1, Downstream/Upstream) Total number of Data Cells
(Path 0/1, Downstream/Upstream) Total number of Bit errors
(Downstream/Upstream) Total number of Errored Seconds
(Downstream/ Upstream) Total number of Severely Errored Seconds
(Downstream/Upstream) Total number of Unavailable Seconds
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sr300nSr360nSr500nSr510nSr550nSr505n