[ 11 ] Optional Paper Feed Roller
Before disassembling or reassembling, be sure to refer to
sembling".
(1)
Remove the optional mechanical block. (Refer to
(2)
Release the hook and remove the gear D. (Refer to
(3)
Remove the one E-ring.
(4)
Remove the shaft holders on the each sides of the optional tray paper feed roller, and remove the
optional paper feed roller.
Shaft holder
January 2005 © TOSHIBA TEC
Optional paper feed roller
Fig.8-79
8 - 55
P.8-1 "8.1 Before Disassembling or Reas-
P.8-49 "[ 6 ] Optional Mechanical Block")
P.8-54 "[ 10 ] Optional Paper Gears")
Shaft holder
e-STUDIO170F Removal/Replacement/Adjustment
E-ring