1.2. Framing the Heater

Framing can be built before or after the heater is set
in place. Framing should be positioned to accommo-
date wall coverings and heater facing material. The
diagram below shows framing reference dimensions.
CAUTION: MEASURE HEATER DIMENSIONS AND
VERIFY FRAMING METHODS AND WALL COVER-
ING DETAILS, BEFORE FRAMING CONSTRUC-
TION BEGINS.
* Note: These dimensions show the center
of the horizontal fl ue pipe. The center of
the framing hole is 1 in. (25 mm) above the
center of the fl ue pipe. Framing should be
constructed of 2 in. x 4 in. (51 mm x 102 mm)
lumber or heavier.
Figure 3. Framing Dimensions
6
D*
A
B
42-5/8 in.
42-1/2 in.
(1.21 m)
(1.08 m)
Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15
WARNING: FRAMING DIMENSIONS AS-
!
SUME USE OF 10 MM (THICK WALL COV-
ERING MATERIALS ON EXTERIOR OF
FRAMING ONLY AND NO SHEETROCK
ON INTERIOR OF FRAMING.
C
D *
E *
23.2 in.
35 in.
53-3/4 in.
(590 mm)
(889 mm)
(1.37 m)
C
A
E*
B