Hybrid Hmf150/200 As A Combination "Wood/Electric" Furnace - Napoleon HYBRID 150 Installation And Operating Instructions Manual

Hide thumbs Also See for HYBRID 150:
Table of Contents

Advertisement

Available languages

Available languages

5.4

HYBRID HMF150/200 AS A COMBINATION "WOOD/ELECTRIC" FURNACE

REQUIRED COMPONENTS:
STEPS #1 - #4
Follow Steps 1 to 4 from SECTION 5.1 - HYBRID HMF150/200 AS AN "ADD ON" TO EXISTING FURNACE.
STEP #5
Completely assemble HMF150/200 in required left or right hand "RA"
confi guration as required.
Locate and level HMF150/200 while maintaining minimum 1.25"
(32mm) clearance space between bottom of furnace and fl oor.
Use the levelling legs to compensate for uneven fl oor and snug the
lock nuts up to furnace base to prevent movement through vibration.
STEP #6
Remove contents of the blower module kit and compare with contents list on "manual" addendum accom-
panying the blower module.
STEP #7
Remove contents of the electric furnace module kit and compare with contents list on "manual" addendum
accompanying the electric furnace module. Refer to step 1.2 for installation instructions for the pressure
differential switch probe according to either left or right RA confi guration.
STEP #8
Place the blower module and the electric furnace module beside each other as per diagram:
ENSURE ELECTRIC FURNACE CONTROL BOX ACCESS PANEL IS FACING TO THE FRONT OF THE
LEFT HAND RA CONFIGURATION
Align holes in the adjacent top and side fl anges,
and secure with 9 x 1/2" hex head wildrill screws.
STEP #9
Place the open side of electric furnace against rectangular inlet window on the side panel of HMF150/200
furnace. Adjust the levelling legs on the blower box module so that the electric furnace module is level and
holes on the mounting fl anges align with pilot holes on side of furnace panel.
• HMF150/200 Hybrid Furnace
• HMFK-BMP50 Blower Box Module
• HMFK-EF15, -EF18, -EF20, -EF25 Electric Furnace Module
(HMFK-EF15 for the HMF150 only, and HMFK-EF25 for HMF200 only)
• HMFK-SOLID or HMFK-GLASS Door Kit
UNIT WITH THE ELECTRICAL HEATER COILS TO THE BOTTOM.
ELECTRIC FURNACE
ELECTRIC FURNACE
BLOWER HOUSING
MODULE
CONTROLS
MODULE
RIGHT HAND RA CONFIGURATION
NOTE
Top/bottom fl ange screws thread into blower. Side
fl ange screws thread into electric unit.
33
LOCK NUT
LEVEL LEG
H3.50
W415-1013 / C / 11.19.13
EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hmf150Hybrid 200Hmf200

Table of Contents