Downloading Computer's Phone Number; Downloading Access Code; Panel Identification Code; Double-Call Timer - DSC PC1832 Reference Manual

Powerseries
Hide thumbs Also See for PC1832:
Table of Contents

Advertisement

Option
Downloading Code
2
DLS Window
3
Call-Back
4
User Call-Up
5
Auto Event Buffer Upload
6-8
For Future Use
NOTE:
To perform DLS via the T-Link module, Option [1], Section
401 must be enable or the number of rings in section 406 must be
programmed.
NOTE:
Option [2] applies to DLS via T-Link as well.
NOTE:
Option [3] and [4] cannot be performed through T-Link.

[402] - Downloading Computer's Phone Number

This telephone number is 32 digits in length.

[403] - Downloading Access Code

This 6-digit hexadecimal code allows the panel to confirm that it is
communicating with a valid downloading computer.

[404] - Panel Identification Code

This 6-digit Hexadecimal code allows the downloading computer
to confirm the identity of the control panel.

[405] - Double-Call Timer

This timer sets the amount of time that can be taken between
calls when using Double Call to contact the panel. Valid entries
are 001 to 255 (seconds).

[406] - Number of Rings to Answer On

The value in this section determines how many rings that the
panel will automatically pick up on in order to establish a DLS
connection. Default value is 000 rings. Valid entries are [000]-
[020].
NOTE:
If Section [401] Option 1 and Section [406] are enabled,
either one will work depending on how the installer calls the pre-
mises.

[499] - Initiate PC-Link Communications

The installer may initiate a PC-Link DLS session between a com-
puter and panel by entering this section in the following manner:
[499] - [Installer's Code] [499].
The installer should already have the PC-Link Cable properly con-
nected between the panel's header and the downloading com-
PGM Output Types [01], [03], [04], [05]-[08], [17]-[18], [33] and [34]
1
Future Use
2
Future Use
3
Output Level
PGM Output Types [03], and [19]-[22]
4
Output Options
On/
Description
Off
ON
User Can Enable DLS Window. The user can use the [*][6][Master Code][5] Command to enable a 6
hour window in which the panel will answer calls for downloading if a successful Double Call routine is
detected. If this option is enabled, the window is open upon power up. The window is on for the full 6
hours if enabled.
OFF
User Can Not Enable DLS Window. The user can not enable a window for DLS calls.
NOTE: Options 1 and 2 are not related. One does not need to be enabled for the other to per-
form its function.
ON
Call-Back Enabled. When the system answers the downloading computer's call, both the computer
and the panel will hang up. The panel will then call the Downloading Telephone Number and connect
with the computer at that number. If more than one downloading computer is to be used, this func-
tion should be disabled.
OFF
Call-Back Disabled. The downloading computer will have immediate access to the panel once it is
identified as a valid system.
ON
User Call-Up Enabled. When this feature is enabled, the user may initiate a single call of the Down-
loading Telephone by entering [*][6][Master Code][6].
OFF
User Call-Up Disabled. An error tone will be generated when [*][6][Master Code][6] is entered.
ON
Auto Event Buffer Upload Enabled. After the panel has communicated the "Event Buffer 75%
Full" event to central station, the panel will call the Downloading Computer's telephone number. DLS
software will then perform an event buffer upload upon successful connection.
OFF
Auto Event Buffer Upload Disabled. After the panel has communicated the "Event Buffer 75%
Full" event to central station, the panel will not call the Downloading Computer's telephone number.
NOTE: This option must be off to ensure proper PGM operation.
NOTE: This option must be off to ensure proper PGM operation.
ON
True Output The output will activate (switch to Ground) when the event occurs.
OFF
Inverted Output The output will de-activate (switch to open) when the event occurs.
ON
Output Pulsed The output will activate for the duration programmed in for the PGM Output Timer
in Section [164]. This default period is 5 seconds.
OFF
Output On/Off The output will toggle between on and off when the corresponding [*][7] command
is entered.
45
puter as well as have the DLS file waiting for the panel to connect
before entering this command.
NOTE:
PC-Link cannot be initiated while the panel is communicat-
ing via the phone line.

5.7 Programmable Output Programming

[501]-[514] - Programmable Output Attributes

PGM output attributes and output type must be programmed for
each PGM output. PGM output options [09] "System Trouble" and
[10] "Latched System Event" have a unique set of attributes listed
below the description of each output type.
PGM attributes return to their default settings when PGM output
options are changed. See the programming worksheets for the
PGM output types defaults.
CAUTION: Select the normal and active states of each PGM
output to ensure that undesirable output states do not
occur after a loss and restore of AC power.
If you program more than one PGM output as the same output
type (e.g. If PGM 1 and PGM 2 are both programmed as [19]
Command Output 1), the settings for output attributes [1], [2] and
[5] must be the same. This does not apply to outputs programmed
as types [09] and [10].
NOTE:
Attribute [3] must be ON for PGM Option [16].

Assigning Partitions to Programmable Outputs

By default, all programmable outputs are assigned to partition 1.
For programmable outputs to work on other partitions, enable or
disable the appropriate partitions in the Partition Assignment pro-
gramming sections.
PGM Output Partition Assignment . . . . . . . . Sections [551] - [564]
PGM Output timer . . . . . . . . . . . . . . . . . . . . . . . . . . .Section [170[