Binary Data Display; Hex Data Programming; Programming Sections; Binary Programming - DSC PC155O Installation Manual

Hide thumbs Also See for PC155O:
Table of Contents

Advertisement

can be turned OFF at once by pressing [0]. When the correct selections
have been made, press [#] to save the selections in memory and return
to the program mode.

Binary Data Display

Zone lights 1 through 4 are used to display the value, in binary format,
of the data as shown in the table below.

HEX Data Programming

Certain programming entries may require the entry of data in HEX
(hexadecimal, or base 16) format. HEX numbering uses the digits 0
through 9 and the letters A through F.
The letters A through F are represented by the number keys 1 through
6. To enter data in HEX format, first press [ ]. The "Ready" light will
flash. Enter the HEX value, then press [ ] again to return to the normal
entry mode. The "Ready" light will stop flashing.
To enter HEX numbers:
A
Enter
[ ][1][ ]
B
Enter
[ ][2][ ]
C
Enter
[ ][3][ ]
Enter [ ] before and after each digit. The last digit in each section does
not require the final asterisk ([ ]) to be entered.

Programming Sections

[00] Binary Programming

This section is normally used upon instruction from factory technical
personnel for specialized programming not covered by the standard
programming instructions.

[01] 1st Phone Number

This is the first telephone number the Communicator will dial. See
Section [25], Communicator Call Direction.
After entering section [01] for programming, enter the telephone
number the same way you would dial it on a touch-tone phone. Press
[#] after the last digit to complete the telephone number programming.
A second dial tone search, as required in a PBX system, can be added
by programming a HEX 'D' between the digits in the phone number
where it is required. To enter a HEX 'D', press [ ] [4] [ ].
Instead of a dial tone search, a pause of 4 seconds can be inserted
between digits in a telephone number.
Enter [ , 2,
] to dial a ' ' (HEX 'B')
Enter [ , 3,
] for a 4-second pause (HEX 'C')
The total number of digits, including dial tone searches and pauses,
must not exceed 16. Remember, press [#] to complete entry of the
telephone number. When complete, enter two digits to program another
section.

[02] 1st Account Code

The 1st Account Code is always transmitted to the 1st telephone number
to identify the customer. Enter a 4-digit number. If the HEX digits 'A' to 'F'
are required, remember to enter [ ] before and after the digit entry.
Where a zero is required in the account code, enter HEX 'A' ( , 1, )
to transmit 10 pulses which will be interpreted as a zero by the
monitoring station receiver.
If a 3-digit code is required, as in 3/1 formats, enter [0] as the LAST
digit. The [0] represents a null digit where no pulses are transmitted.

[03] 2nd Phone Number

This is the second telephone number to which the communicator will
dial. See [01] for programming instructions.

[04] 2nd Account Code

The second account code is always transmitted to the 2nd telephone
number. See [02] for programming instructions.

[05] to [10] Reporting Codes

These sections are used to program the communicator reporting
codes. A reporting code is transmitted along with the account code
with each transmission. If the reporting codes are not programmed, no
D
Enter
[ ][4][ ]
E
Enter
[ ][5][ ]
F
Enter
[ ][6][ ]
transmission will be sent when an event takes place (i.e. alarm, restoral,
opening / closing, trouble, etc.). To prevent a transmission from being
sent for any event in the following sections, leave it unprogrammed or
enter [00] as the reporting code.
Section [05] and [06] each have 6 reporting codes. Sections [07], [08]
and [10] each have 7 reporting codes, while section [09] has 8
reporting codes. Once a section is entered, the system expects a
series of 2-digit numbers to be entered. The keypad beeps twice and
the "Armed" light flashes after each 2-digit entry. After the last 2-digit
number is entered, programming of the current section is complete.
Value
Zone 1
Zone 2
Zone 3
Zone 4
Light On
Light Off
*
See Hex Data Entry instructions
The keypad gives a series of beeps, the "Ready" light goes OFF and
the "Armed" light comes ON. The keypad is then ready to accept the
next 2-digit section number for programming.
When changing reporting codes in a section, you can scroll to the code
you wish to change by pressing the [F] key. Only codes actually
changed will be altered in the EEPROM. Press [#] to exit from the
programming sequence.

[05] Zone Alarm Reporting Codes

Once Section [05] is entered, the panel expects 6 2-digit numbers for
the Alarm Reporting Codes for zones 1 to 6. These codes are used by
the communicator when there has been an alarm on zones 1 to 6.
Listed below are several programming examples and the resulting
transmission using different formats for the reporting codes. Obtaining
different formats requires entering data in the Account Code Section
[02] or [04], the Reporting Code Sections [05] to [10], and the
Communicator Format Section [23].
3/1 FORMAT - Non-extended reporting requires:
• 3-digit account code in sections [02] or [04].
i.e. Enter 1230 for account code 123
• Format Code [0], [1], [2], [3], [4] depending on
receiver type in section [23].
• Single line digit Alarm Reporting Code Section [05]
i.e. Enter [30] for single digit code 3 (0 = no pulses)
TRANSMISSION SENT:
4/2 FORMAT - Non-extended reporting requires:
• 4-digit account code in sections [02] or [04].
i.e. Enter 1234 for account code 1234
• Format Code [0], [1], [2], [3], [4] depending on
receiver type in section [23].
• 2-digit Alarm Reporting Code in section [05]
i.e. Enter [31] for 2-digit code 31
TRANSMISSION SENT:
3/1 FORMAT - Extended reporting requires:
• 3-digit Account Code in section [02] or [04]
i.e. Enter 1230 for code 123
• Format Code [8], [9], [A], [B], [C] depending on
receiver type in section [23]
• 2-digit Alarm Reporting Code in section [05]
i.e. Enter [31] for 2-digit code 31
TRANSMISSION SENT:
Hex Data Entry*
123 3
1234 31
1st ROUND
123 3
2nd ROUND 333 1
7