ELECTRICITY
Regulator/Starter motor relay/Ignition
unit/Starter resistor/HT coil
- Remove the battery access door.
- Disconnect and remove the battery.
- Remove the battery bracket.
- Disconnect and remove the electrical
components.
• The ignition unit, starter relay and lighting
resistance are attached to a removable
holder.
• The regulator and high tension coil are
attached to the chassis.
Checking the starter motor relay
A
Condition
Disconnect and
remove the starter
Apply a voltage of 12 V to the A
motor relay.
40
Reproduction or translation, even partial, is forbidden without the written consent of Peugeot Motocycles
B
Operation
terminls on the relay.
The relay must trip.
Ω
B
Measurement
Between terminals A
Between terminals B
Between terminals B
Ω
+12V
-
A
Standard values
R=3.6 Ω
±10%
R=∞ Ω
R=0 Ω