Installing the neutralising system with booster pump
The Neutrakon neutralising system type 08/BGN with
booster pump for intensive pH regeneration, which is
available as a Wolf accessory, can be slid under the boiler.
Firstly remove the wooden slats for boiler transport.
The booster pump can be mounted on the boiler crossbar.
Ensure even distribution of the granulate. The inlet and drain
must not be covered with granulate.
Observe the installation and maintenance instructions supplied
with the neutralising system.
Neutrakon neutralising system installation
Type 8/BGN:
- Remove black plug-in strainers (transport safeguard) on
the inlet and drain and fit hose connections with pipe
strainer. HT pipe connection possible.
- Distribute the granulate evenly by shaking the Neutrakon.
The granulate must not completely cover the inlet and
drain (risk of blockage).
- Secure booster pump to the crossbar with Velcro strip.
- Fit air hose to the booster.
- Connect the booster cable with the plug on the cable set.
- Always fit the booster above the neutralising system to
prevent condensate flowing into the booster.
The booster pump must always be installed higher than
the neutralising system. Danger of electrocution!
Function check
The first fill of granulate lasts for at least one year with approx.
2000 hours of operation p.a., provided the system is operated
correctly. To ensure smooth functioning, the neutralising
system must be checked at least once a year.
1. Check fill level. If the granulate level is below the maximum
mark (red label), it needs refilling.
Neutralisation can only take place when the water flows
through the granulate. The granulate fill level must always
be above the condensate level.
2. Measure pH value with pH indicator strip. if the pH value is
below 6.5, the neutralising system needs servicing.
22

15. Neutralising system (accessory)

Neutralising system
Condensate lifting system
Wooden slat
Air hose
Condensate lifting system
Booster and condensate pump connection
(connections on cable set behind the strut)
Booster pump mounted on
crossbar
3063772_201507