Heat & Glo Everest Owner's Manual page 26

Hide thumbs Also See for Everest:
Table of Contents

Advertisement

Top Vent - Vertical Termination
No Elbow
V
= 40 ft. Max. (12.4 m)
1
V
= 3 ft. Min. (914 mm)
1
Note: If installing a vertical vent/
termination off the top of the ap-
pliance, the fl ue restrictor should
be used.
Figure 7.6
26
V
1
Heat & Glo • Everest • 750-900 Rev. W • 10/14
Vertical Baffl e
If your vertical vent component is over 10 feet, you may
want to install the included vertical baffl e to improve fl ame
appearance. Vertical baffl e is located in the bag containing
the instruction manual. Center the vertical baffl e on the fi ve
inch vent being used, and with self tapping screws secure
the baffl e to the inside of the fi rebox. See Figure 7.7.
With vent runs of 30 feet or more without elbows, an
additional baffl e (SRV750-152) is to be used with the
supplied baffl e. This is a service part and is to be purchased
separately.
VERTICAL
BAFFLE
FIREPLACE BOTTOM
Figure 7.7 Vertical Baffl e
5" EXHAUST
PIPE

Advertisement

Table of Contents
loading