Heat & Glo EXCLAIM-50 Owner's Manual
Heat & Glo EXCLAIM-50 Owner's Manual

Heat & Glo EXCLAIM-50 Owner's Manual

Wood burning fireplace
Hide thumbs Also See for EXCLAIM-50:
Table of Contents

Advertisement

Quick Links

Models:
EXCLAIM-50
Wood Burning Fireplace
Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING
If the information in these instruc-
tions is not followed exactly, a
fi re may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not overfi re. Overfi ring will void your
warranty.
• Comply with all minimum clearances to
combustibles as specifi ed. Failure to
comply may cause house fi re.
Installation and service of this fi replace
should be performed by qualifi ed personnel.
Hearth & Home Technologies suggests NFI
certifi ed or factory-trained professionals, or
technicians supervised by an
NFI certifi ed professional.
NOTICE
DO NOT DISCARD THIS MANUAL
Read, understand
and follow these
instructions for safe
i n s t a l l a t i o n a n d
operation.
Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08
Owner's Manual
Installation and Operation
Leave this manual with
party responsible for
use and operation.
WARNING
Hot screen/mesh and glass doors will cause burns.
DO NOT touch screen/mesh or glass doors until
cooled
NEVER allow children to touch screen/mesh or glass
doors
Keep children away
CAREFULLY SUPERVISE children in same room as
fi replace.
Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other
fl ammable materials.
Keep clothing, furniture, draperies and other
fl ammable materials away.
WARNING
Fire Risk
For use with solid wood fuel or decorative
gas appliance only.
DO NOT install unvented gas logs.
HOT SURFACES!
Screen/mesh, glass doors
and other surfaces are hot
during operation AND cool
down.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo EXCLAIM-50

  • Page 1 • For use with solid wood fuel or decorative technicians supervised by an gas appliance only. NFI certifi ed professional. • DO NOT install unvented gas logs. Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 2: Congratulations

    ADJUST DAMPER TO THE FULLY OPEN POSITION. 1915 W. SAUNDERS ST., MT. PLEASANT, IA 52641. Note: An arrow ( ) found in the text signifi es change in content. Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 3: Table Of Contents

    B. Chimney Components H. Inspect Fireplace and Components D. Service Parts Framing & Clearances E. Contact Information A. Select Fireplace Location B. Clearances C. Sidewalls/Surrounds D. Frame the Fireplace Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 4 HHT reserves the right to make changes at anytime, without notice, in design, material, specifications and prices and the right to discontinue styles and products. Feb 2006 Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 5: Listing And Code Approvals

    NOTICE: This fireplace is tested and approved as a decorative fi replace. It should not be factored as a primary heat source in residential heating calculations. Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 6: User Guide

    WARNING! DO NOT operate fi replace before reading and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury. Figure 2.1 General Operating Parts Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 7: Seasoned Wood

    fi rewood, placed to allow combustion air and fl ames between them. CAUTION! Odors and vapors released during initial operation may be irritating to sensitive individuals. Open windows for air circulation. Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 8: Glass Doors

    BEFORE lighting fi re. 48 in. (1219 mm) Clear Space Front of Fireplace 24 in. (610 mm) Clear Space Sides of Fireplace (from the FP opening) Figure 2.3 Clear Space Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 9: Wood Fuel

    fi relogs that have been evaluated for the application in manufactured fi replaces and refer to fi relog warnings and caution markings on packaging prior to use. Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 10: Maintainance And Service

    Top Cover Chimney Slip Section TR11/TR11T TCT1175 ST1175 Round Termination Cap Terra Cotta Square Termination Cap Termination Cap Figure 3.1 Chimney & Termination Cap Cleaning Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 11: Check Firebox Refractory

    • Light deposits Use household glass cleaner • Heavy deposits Use wood ash on damp cloth or, Use commercial fi replace glass cleaner (consult with your dealer) Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 12: Troubleshooting Guide

    Add glass doors to slow down air fl ow. Overdrafting Check for correct vent height; too much vertical height creates overdrafting. Check location of vent termination (refer to chimney assembly section). Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 13: Getting Started

    (1.83m) off (Section 11) ground level. Hearth extension Outside (Section 11) combustion air Factory-built fireplace (Section 7) Protective metal hearth strip(s) (Section 7) Figure 5.1 Typical Fireplace System Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 14: Design And Installation Considerations

    Tight sealing construction of the structure • Mechanical exhausting devices NOTICE: Hearth & Home Technologies Inc. recommends • Improper location of the chimney the use of direct vent fi replaces in basements. Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 15: Locating Fireplace & Chimney

    • Below adjacent structure Recommended: • Insulated exterior chase • Lower roof line in cooler climates • Avoid outside wall Windward Leeward Multi-level Roofs Figure 5.2 Recommended Chimney Locations Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 16: Tools And Supplies Needed

    Misc. screws and nails G. Fireplace System Requirements This fi replace system requires: • Refractory Assembly • Grate Assembly • Outside Air Hoods Duct must be installed, but sold separately. Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 17: Framing & Clearances

    77 in. 77 in. all configurations (1956 mm) (1956 mm) 48 in. 30-3/8 in. (1219 mm) (772 mm) 24 in. (610 mm) Figure 6.1 Fireplace Locations (Framing dimensions shown) Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 18: Clearances

    1-1/2 in. (38mm) from side of appliance (except at nailing flanges where it is 1/2 in. (13 mm) 0 in. from floor Figure 6.2 Air Space Clearances Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 19: Sidewalls/Surrounds

    If outside air duct has 30 1/2 in.* no bend, this dimension may be (772 mm) reduced as long as minimum clearances are met. Figure 6.4 Framing the Fireplace Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 20: Installation Of Fireplace

    (Figure 7.6), Figure 7.2 Bend Refractory Brackets Back Down Replace screws removed from fi replace. Brackets can be used to anchor fireplace in position. Figure 7.6 Removing Shipping Brackets Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 21: Position The Fireplace

    fl oor. • Check fi replace opening for square to ensure proper fi t of glass doors. Measure diagonals of fi replace opening to make sure they are equal. Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 22: Install Refractory

    Figure 7.11. Be sure to position it so the retainer notch is at the top. Figure 7.13 Install Side Refractory Figure 7.14 Side Refractory Installed Figure 7.11 Install Back Refractory Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 23: Install Outside Air Kits

    Figure 7.17. except small dip for cold air trap which will help prevent flow of cold air). Figure 7.18 Outside Combustion Air Placement Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 24 • Check for light leaks with a fl ashlight and seal with duct tape and/or insulation. Figure 7.20 Bending Tabs on Outside Air Kit Collar Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 25: Chimney Assembly

    Ceiling firestops are required where chimney passes through ceiling or floor Figure 8.1 Typical Chimney System - Guidelines for Chimney System Installation Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 26: Chimney Requirements

    (bottom of fireplace Knockout SL1106 4-3/4 to top of starter collar) SL1112 10-3/4 SL1118 16-3/4 SL1136 34-3/4 Figure 8.2 Chimney Requirements SL1148 46-3/4 1187 * Dimensions refl ect effective height. Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 27: Using Offsets/Returns

    98 7/8 2511 Proper assembly of air cooled chimney parts results in an overlap of chimney joints of 1-1/4 in. (32 mm). Effective length is built into this table. Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 28: Assemble Chimney Sections

    Vertical straight runs of chimney must be supported every 35 ft (10.7 m). D. Install Chimney Air Kit • Required in Canada. • Follow instructions provided with this accessory. Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 29: Install Ceiling Firestops

    fi restop opening and chimney pipe except where they enter the attic or leave the warm air envelope of the home (use 600° F sealant). Catalog # FS538 FS540 Figure 8.5 Installing the Ceiling Firestop Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 30: Install Attic Insulation Shield

    17 in. (432 mm) diameter 6 Tabs bent in 90° Insulation Insulation 13 in. Ceiling Firestop Pipe (330 mm) Figure 8.8 Install Attic Insulation Shield (fi restop below ceiling) Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 31: Cut Out Hole In Roof

    Caulk the fl ashing plate and roof junction as well as the vertical seam on the fl ashing. All nail heads must be caulked with a roofi ng sealant. Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 32: Chimney Termination Requirements

    Refer to the installation instruc- 6 in. 20 in. (152 mm) min. (508 mm) min. tions supplied with the decorative cap cover. Multiple Chimney Locations Figure 8.10 Multiple Chimney Locations Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 33: Chase Installations

    Failure to prevent contact between insulation or other Insulation Insulation materials and chimney system may cause overheating False Ceiling False Ceiling and fi re. Chimney Figure 9.1 Chase Assembly Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 34: Install Fireplace & Chimney

    Chase Top Construction Termination cap pipe and chimney section must be snapped together to maintain an overlap of 1-1/2 in. (38 mm). Figure 9.4 Installing a TR11 Round Termination Cap Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 35 Minimum Height chimney section Chase Top Chase Chimney Pipe Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm) Figure 9.6 Installing an ST1175 Square Termination Cap Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 36: Shrouds

    23 x 23 737 x 737 584 x 584 Min. Opening Width 26 x 26 20 x 20 660 x 660 508 x 508 Figure 10.2 Open Top Shroud Dimensions Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 37 34 x 34 34 x 34 864 x 864 864 x 864 Min. Height Above Radiation Shield Min. Opening Width Min. Opening Height Figure 10.4 Roofed Style Shroud Dimensions Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 38: Finishing

    5-1/8 in. Common Brick 0.20 5-1/8 in. Ceramic Tile 12.50 0.08 12-1/4 in. Armstrong™ Privacy Guard Plus 0.46 2.18 1/2 in. Marble 14.3-20.0 0.07-0.05 14-5/8 in. - 20-3/8 in. Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 39 Finishing Materials Framing Material 1/2 in. Micore Figure 11.5 Raised Platform Hearth Extension-Finishing Materi- Protective Metal Floor or equivalent Hearth Strips insulation Figure 11.3 Raised Platform Hearth Extension Detail Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 40 Finished hearth must NOT extend above this level. Finished Floor 30 in. Min. Hearth Extension Micore Noncombustible Material Protective Metal Hearth Strip Figure 11.8 Flush Hearth Extension Side View Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 41: Finishing Material

    2 in. (51 mm) Figure 11.10 Decorative Facing Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 42: Combustible Mantel

    12 in./305 mm MAXIMUM 20 in./508 mm MINIMUM Seal joint with non-combustible sealant Measured from top of fireplace opening Figure 11.11 Clearances to Mantels or other Combustibles above Fireplace Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 43: Sidewalls/Surrounds

    Combustible or non-combustible mantel legs, surrounds and stub walls may be constructed per Figure 11.12. Figure 11.12 Mantel Leg or Wall Projections (acceptable on both sides of opening) Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 44: Accessories

    Repack beyond 4 in. (102 mm) Insulation from fireplace side. Knockout 4 in. (102 mm) Figure 12.1 Gas Line Installation Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 45: Reference Materials

    Reference Materials A. Fireplace Dimensions Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 46: Optional Components

    (1676 mm) 20 in. (508 mm) 1/2 in. (13 mm) HX4 Hearth Extension Bi-fold Glass Doors See your Heat & Glo Dealer for a complete list of optional components. Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 47: Chimney Components

    5-1/4 in. (527 mm) (279 mm) (133 mm) 4 in. (102 mm) 13 in. Outside Diameter (330 mm) 13 in. (330 mm) SL11 Vent Stabilizer CAK5A Chimney Air Kit Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 48 28 in. (330 mm) 39-7/8 in. (711 mm) (1013 mm) CB576 Chimney Joint Band RF571 Roof Flashing 10 3/4 in. 26 in. TR-TVK TR Top Vent Kit CT-11A Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 49 20 in. (508 mm) LDS-BV Decorative Shroud Catalog # 12-1/2 15-1/2 17 in. LDS-BV (432 mm) 9-3/8 in. (238 mm) 9-1/4 in. (235 mm) TCT1175 - Terra Cotta Cap Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 50: Service Parts

    D. Service Parts Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 51 This page intentionally left blank. Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...
  • Page 52: Contact Information

    6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Heat & Glo • EXCLAIM-50 • 4013-041 • Rev T • 08/08...