RS-232 Demonstration Program
If an RS-232 scanner is not communicating with your IBM
compatible PC, key in the following BASIC program to test that
the communication port and scanner are working.
This program is for demonstration purposes only. It is only
intended to prove that cabling is correct, the com port is working,
and the scanner is working. If the bar code data displays on the
screen while using this program, it only demonstrates that the
hardware interface and scanner are working. At this point,
investigate whether the application software and the scanner
configuration match.
If the application does not support RS-232 scanners, a software
wedge program that will take RS-232 data and place it into a
keyboard buffer may be needed. This program tells the PC to
ignore RTS-CTS, Data Set Ready (DSR) and Data Carrier Detect
(DCD) signals. If the demonstration program works and yours still
does not, jumper RTS to CTS and Data Terminal Reading (DTR)
to DCD and DSR on the back of your PC.
10
CLS
20
ON ERROR GOTO 100
30
OPEN "COM1:9600,S,7,1,CSO,DSO,CD0,LF" AS#1
35
PRINT "SCAN A FEW BAR CODES"
40
LINE INPUT #1, BARCODE$
50
PRINT BARCODE$
60
K$ = INKEY$: IF K$ = CHR$(27) THEN GOTO 32766
70
GOTO 40
100
PRINT "ERROR NO."; ERR ;"PRESS ANY KEY TO
TERMINATE."
110
KK$ = INKEY$: IF K$ = ""THEN GOTO 110
32766 CLOSE: SYSTEM
32767 END
29