TK-782
Item
Condition
7. Maximum
1) Set test mode
deviation
Connect AG to the MIC
terminal.
Select "MAX" in tuning mode. Oscilloscope
"nL MAX"
AG : 1kHz/40mV
Deviation meter filter
LPF : 15kHz
HPF : OFF
De-emphasis : OFF
PTT : ON
2) "nC MAX"
PTT : ON
3) "nH MAX"
PTT : ON
4) "w MAX"
PTT : ON
8. MIC
1) Set test mode
seisitivity
CH : CH1 - Sig1
check
AG : 1kHz/4mV
PTT : ON
9. QT deviation 1) Set test mode
Select "QT" in tuning mode.
"nL QT"
Deviation meter filter
LPF : 3kHz
HPF : OFF
PTT : ON
2) "nC QT"
PTT : ON
3) "nH QT"
PTT : ON
4) "w QT"
PTT : ON
10. DQT
1) Set test mode
deviation
Select "DQT" in tuning mode.
"nL DQT"
Deviation meter filter
LPF : 3kHz
HPF : OFF
PTT : ON
2) "nC DQT"
PTT : ON
3) "nH DQT"
PTT : ON
4) "w DQT"
PTT : ON
72
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Rear
ANT
Deviation
panel
meter
AF VTVM Front
MIC
AG
panel
Adjustment
Parts
Method
4.1kHz (Wide)
+0Hz/–50Hz (Wide/Narrow)
2.05kHz (Narrow)
(According to the
larger +, –)
± 3kHz± 0.2kHz (Wide)
Check
± 1.5kHz± 0.05kHz (Narrow)
± 50Hz (Wide/Narrow)
0.75kHz (Wide)
0.35kHz (Narrow)
± 50Hz (Wide/Narrow)
0.75kHz (Wide)
0.35kHz (Narrow)
Specifications/Remarks

Hide quick links: