14. TESTOPERATION
1
2
The test operation
must
be carried
out after the entire
installation.
Please confirm the following points before the test operation:
The indoor unit and outdoor unit are installed properly.
Tubing and wiring are correctly completed.
The refrigerant pipe system is leakage-checked.
The drainage is unimpeded.
The heating insulation works well.
The ground wiring is connected
correctly.
The length of the tubing and additional
charge
amount
have been recorded.
The power voltage
matches
rated the voltage of the air
conditioner.
There is no obstacle at the outlet and inlet of the outdoor
and indoor units.
The gas-side
and liquid-side
service
valves
are both
completely
open.
The air conditioner
is pre-heated by turning on the power.
3
[]
Test operation
Set the air conditioner
to the
cooling mode with the remote
controller,
and check
the following
points.
If there is any
malfunction,
please
resolve
it according
to the chapter
"Troubleshooting"
in the "Owner's Manual".
1) The indoor unit
a. Whether
the buttons on the remote controller
works
well.
b. Whether the air flow louver move normally.
c. Whether the room temperature
is well adjusted.
d. Whether the indicator lights normally.
e. Whether the temporary
switch on the unit works well.
f. Whether the drainage is normal.
g. Whether
there is abnormal
vibration
or noise during
operation.
h. Whether
the air conditioner
works
well
in heating
mode(heat pump model).
2) The outdoor unit
a. Whether there is abnormal vibration
and noise during
operation.
b. Whether
the exhaust
air, noise,
or condensation
influence your neighborhood.
c. Whether
there
is any
refrigerant
leakage
during
operation.
_k
CAUTION
A 3 minute delay is normal when restarting the unit for
compressor protection.
The Specification
of Power(indoor
power supply)
[] Table 13-1
1Phase
1Phase
1Phase
208/230V
208/230V
208/230V
15
15
15
The Specification
of Power(outdoor
power supply)
[] Table 13-2
1Phase
1Phase
208/230V
208/230V
15
15
1Phase
1Phase
1Phase
1Phase
1Phase
208/230V
208/230V
208/230V
208/230V
208/230V
20
15~20
25
50
55
The specification
of power for the invert type air conditioner(independence
power supply)
l!
Table 13-3
B
1Phase
220/230V
15
1Phase
208/230V
20~15
1Phase
220/230V
15
1Phase
208/230V
20
1Phase
220/230V
15
1Phase
208/230V
25
1Phase
220/230V
15
1Phase
208/230V
50
1Phase
220/2 30V
15
1Phase
208/2 30V
55
2!