The drain pipe installation for the unit with pump.
............................................................
3,28;4_2_..........
iI
,
,
I/1-1.5m
]L .......
1/50
i
FJg.lO-1
The drain pipe installation
for the unit without pump.
Fig. 10-2
[]
Drainage
test
• Check whether
the drainpipe
is unhindered,
• New ly built
houses
should
have this
test done
before
paving the ceiling.
[]
The unit with pump,
1
Remove the test cover, and stow about 2000ml water in the
water pan.
2
Operate the air conditioner
in "COOLING"
mode. The sound of
the drain pump should be noticeable.
Check whether the water
is discharged well (1 min lag is possible, according to the length
of the drain pipe), and check whether the water leaks from the
joints.
3
Power off the air conditioner
and recover the cap.
[]
The unit without pump.
stowtuL
Fig. 10-5
Stow
2000ml
water
in the
water
pan through
the stow
tube,check whether the drainpipe is unhindered.
Install
the drain joint
of the outdoor
unit
(For Heat Pump
Models)
Fit the seal into the drain joint, then insert the drain joint into the
base pan hole of outdoor, rotate 90 ° to securely assemble them.
Connect the drain joint with an extension
drain hose (Locally
purchased)to
avoid condensate
from draining off the outdoor
unit during the heating mode.
Test cap
Fig. 10-3
Fig. 10-4
Seal
Base pan
,__DD
Seal
rain
joint
Fig.
10-6
NOTE
All the figures in this manual are for illustration
purposes only.
They may differ slightly from the air conditioner you purchased.
11. FRESH AIRDUCTINSTALLATION