Install The Connecting Pipe - Carrier 40MB*D Installation Instructions Manual

Ducted heat pump split system sizes 09 to 48
Hide thumbs Also See for 40MB*D:
Table of Contents

Advertisement

Table 6-2
Outdoor Unit
(_
Vibration-proof
rubber
Anchor Bolt M 10
Drainage (Wide 3.94in/100×Depth
5.9in/150)
(_
Drainage
Mortar Hole (¢3.94in100×Depth
5.9in/150)
NOTE: Make sure 3-4 degree of angel is kept between the unit and
the floor when the unit is installed in the low temperauture
and humid environment.
Make sure the ice on the chassis of the outdoor unit can be
dealt with when the unit is installed in the low temperature
and humid enviroment.
The outdoor unit should be installed in amounting rack 11.81in
/30cm high.The enviroment
temperature should be above
0 °"
The machine must be installed indoor.
°
NOTE:the
table
above
refers
to the liquid
tube.
°
NOTE:The
number
of bends
is up to the length
of the max
height
drop.Usually
for each
32.8ft/10m
need a bend.
_I_
CAUTION
All
field
piping
must
be
provided
by
a
licensed
refrigeration
technician
and
must
comply
with
the
relevant local and national
codes.
Prevent air, dust, or other impurities from entering
in the
pipe system
during
installation.
Insulation
pipe shall be used to the gas piping
and the
liquid piping.
Otherwise,
condensation
may occur.
7.2
The Procedure
of Connecting
Pipes
1
Measure
the
required
length
of the
connecting
pipe,
then create
it per the following
steps.
7.
INSTALL THECONNECTING P IPE
7.1
Preparation
and Caution
Before installation
make sure the height difference,
the length
of refrigerant
pipe, and the number
of the bends between
the
indoor
unit and outdoor
unit meet the following
requirements:
Table 7-1
unit: ft/m
32.8ft/10
16.4ft/,'
82.02ft/25
39.37ft112
I
82.02ft/25
49.21ftP
164.04ft/50
82.02ft/25
I
The outdoor
unit is charged
with
rating
refrigerant
amount
in
the factory.Additional
charges
refer to the table below:
Table 7-2
[]
Connect the indoor unit first, then the outdoor unit.
Bend the tubing in a proper way. Do not twist the pipe.
Bend the pipe with thumb
min-radius
3.94in/100mm
Fig. 7-1
Put some refrigerant
oil on the surfaces
of the flare pipe
and the joint nuts then wrench it for 3~4 rounds with your
hands before you fasten the flare nuts.(Refer to chart 16)
Use frozen oit
i-
Fig.7-2
Be sure to use two wrenches simultaneously
when you
connect or disconnect
the pipes.
_
Make the ends straight
Fig.7-3
Piping
Additional refrigerant charge(between
standard-Max
piping length)
Gas Pipe(size-connection
type
Liquid Pipe(size-connection
type
System size
Oz/ft(g/m)
in(mm)
in(mm)
9K
0.16(15)
3/8(9.52)
1/4(6.35)
12K
0.16(15)
1/2(12.7)
1/4(6.35)
18K
0.16(15)
1/2(12.7)
1/4(6.35)
24K
0.32(30)
5/8(16)
3/8(9.52)
36K
0.32(30)
5/8(16)
3/8(9.52)
48K
0.32(30)
5/8(16)
3/8(9.52)
]5