4 Replacement Procedures
4.26 Fluorescent lamp
4.26.7 Replacing the 15.0 Inch XGA Sharp Fluorescent lamp
Disassembling the 15.0 Inch XGA Sharp Fluorescent lamp
To disassemble the 15.0-inch XGA Sharp fluorescent lamp, follow the steps below and refer
to figures 4-98 to 4-107.
1. Turn the LCD module face down, and remove the protection cover S (A), protection
cover G (B), fixing tape (C) and fixing tape for lead wire (D).
NOTE: 1) Be careful not to damage the TCP or chips.
2) The protection cover G is reused. Discard the other tapes removed.
(A) Protection cover S
(C) Fixing tape
(B) Protection cover G
(D) Fixing tape for lead wire
Figure 4-98 Replacing 15.0 Inch Sharp fluorescent lamp (XGA) (1)
4-112
Satellite A40 Maintenance Manual (960-458)