Draining the Unit
When the portable air conditioner is in cooling mode or dehumidify
mode, it will remove moisture from the air. The condensed water
from the air will be collected in an internal reservoir and will be
evaporated and exhausted out of the exhaust hose. However, in
very humid conditions, the internal reservoir may fill completely.
This causes the air conditioner to turn off to avoid overflowing the
internal reservoir. When water tank is full a buzzer will sound eight
times and on the LED window will display error code "H8".
Direct drainage
1. Remove the rubber drain plug from the drain port.
2. Connect a drain hose to the drain port.
The portable air conditioner will now drain through the drain hose.
Please note that this unit has no drain pump; all water will drain
with gravity only, i.e., only "downhill."
Installing the Filter
Your portable air conditioner ships with a carbon filter to help
remove any unwanted odor from the room. It is recommended you
replace the filter every two to three months, or as needed. It is also
necessary to clean the pre-filter periodically (see page 15 for
maintenance instructions). Follow the steps below to install the
carbon filter:
1. Shut off the unit if it is on. In the rear of the unit pull the air filter
grille from the side.
2. Place the carbon filter between the grille and the pre-filter.
3. Close the grille.
9