Page 1
Conditioner with Dehumidifier MODEL: AP10002BL CAUTION: READ ALL SAFETY PRECAUTIONS IN THIS MANUAL BEFORE SERVICING THE UNIT EdgeStar, 8606 Wall St, Suite 1800, Austin, TX 78754 support.edgestar.com • service@edgestar.com • edgestar.com *Warranty service should be performed by an authorized service representative only.
SAFETY PRECAUTIONS WARNING: This manual and the information contained herein is intended for use by certified technicians. The manufacturer or seller is not responsible for the interpretation or misuse of the information provided, nor does it assume any liability in connection with its use. The safeguards and warnings indicated in this manual do not cover all possible conditions which may occur.
Electrical Safety Do not exceed the power outlet ratings. It is recommended that the unit be connected to its own circuit. A standard electrical supply that is properly grounded in accordance with the National Electrical Code and all state and local codes and ordinances is required. ...
General Safety Always unplug an appliance from the power supply before attempting any service. Disconnect the power cord by grasping the plug, not the cord. Do not allow children or pets to play on or in the appliance. ...
1 Specifications Parameter Unit Value Model AP10002BL Rated Voltage Rated Frequency Power Phases Supply Cooling Capacity Btu/h 10000 Heating Capacity Btu/h Cooling Power Input 1120 Heating Power Input Cooling Power Current Heating Power Current Rated Input 1280 Rated Current 12.6...
Page 7
Compressor Model YZG-A082AFY2D2T1 Compressor Oil RB68EP Compressor Type Rotary L.R.A. Compressor RLA Compressor Power Input Overload Protector HPA-336 Fan Type Centrifugal Diameter Length(DXL) inch 5 3/4;4 1/4 Compress Fan Motor Speed(H/M/L) r/min 1190/1090/990 Output of Fan Motor Fan Motor RLA Fan Motor Capacitor µF Form...
Page 9
Part Name Part Name Front Panel Assembly Filter Sub-assembly 2 Front Panel 2 Front Grill Guide Louver 7 Water Retaining Box Guide Louver 6 Cover of Remote Control Box Guide Blade Lever 2 Remote Control Box Front Case Cable Cross Plate Display Board Wire Clamp Membrane...
4 PCB Diagram No. Item Neutral wire connectors Varistor Fuse Compressor relay Buzzer Display board connectors Water level switch connector Condenser temperature sensor connector Room/ambient temperature sensor connector 10 Frost sensor connector 11 Louver/Stepping motor 12 Flinger/Draw water motor connector 13 Condenser fan connector connector 14 NA for this model...
6 Modes and Operating Conditions 6.1 Temperature Parameters Indoor preset temperature (Tpreset) Indoor ambient temperature (Tamb.) 6.2 Cooling Mode When Tamb ≥ Tpreset +1ºC(2ºF) the unit operates in cooling mode. The compressor runs and the indoor fan operates at the set fan speed. ...
6.5 Auto Mode In auto mode standard cooling Tpreset=77ºF(25ºC); standard heating Tpreset=68ºF(20ºC) When Tamb > 79ºF(26ºC) the unit runs in auto cooling mode. When Tamb < 68ºF(20ºC) the unit runs in auto fan mode. If the unit is operating in fan mode and 68ºF(20ºC) ≥ Tambient ≥ 73ºF(23ºC), the unit will stay in fan mode.
7 Troubleshooting 7.1 Troubleshooting Guide Problem Possible Cause Solution Wall plug is disconnected. Insert plug firmly into proper wall outlet. House fuse blown or circuit breaker Replace fuse with time delay type or reset circuit tripped. breaker. Press the RESET button on the power cord. If Power cord is tripped.
protection (H8 error) Water flinger motor is defective. Replace water flinger motor. occurs frequently. Check wire connections. Repair or tighten any Wire connections faulty. Fan louvers do not broken or loose connections. swing. Fan swing motor damaged. Replace motor. When unit is turned on or off the outer Normal sound.
Page 16
Sensor is defective. Replace sensor. Main PCB is defective. Replace PCB. Low refrigerant Find leak and repair. charge due to leak Recharge refrigerant. or defect. The coils are dirty or the air inlet or outlet is blocked.
Page 17
The coils are dirty or the air inlet or outlet is blocked. Clean coils and/or move/remove obstructions. Fan is not running or set too low. Increase fan speed or replace fan if defective. Overload protection. Compressor is defective. Replace compressor. ...