EdgeStar AP10002BL Owner's Manual
Hide thumbs Also See for AP10002BL:

Advertisement

Portable Air Conditioner
Owner's Manual
AP10002BL
For more information on other great EdgeStar products on the web, go to http://www.edgestar.com

Advertisement

Table of Contents
loading

Summary of Contents for EdgeStar AP10002BL

  • Page 1 Portable Air Conditioner Owner’s Manual AP10002BL For more information on other great EdgeStar products on the web, go to http://www.edgestar.com...
  • Page 2: Important Safety Information

    2. Press the TEST button on the LCDI plug. This should trip the plug and cut the power to the air conditioner. If the plug does not trip and you are able to turn on the unit, please contact EdgeStar support.
  • Page 3: Table Of Contents

    ENERGY SAVING GUIDE ................... 14 MAINTENANCE ....................15 ................... 15 LEANING THE UNIT ................. 15 LEANING THE PRE FILTER ................16 REPARATION FOR TORAGE TROUBLESHOOTING ..................17 ERROR CODES ....................20 SPECIFICATIONS ....................21 EDGESTAR LIMITED WARRANTY ..............22 Edgestar Portable Air Conditioner...
  • Page 4: Introduction

    Introduction Thank you for purchasing this EdgeStar portable air conditioner. We are glad you chose us. We believe that your purchase of this product opens a relationship between you and EdgeStar. We will provide the customer support needed to nurture that relationship.
  • Page 5: Parts Identification

    1. Control Panel 2. Handle 3. Remote Control Holder 4. Air Vent 5. Louvers (Vertical & Horizontal) 6. Castors (4) 7. Air Inlet 8. Filter Grill 9. Air Outlet 10. Power Cord Hook 11. Power Cord Back View Edgestar Portable Air Conditioner...
  • Page 6: Back View With All Accessories

    Back View with all accessories Parts Included Suggested Tools- Phillips Screw Driver (Medium sized), Tape Measure/Ruler, Scissors, Saw (In the event that your window panel needs to be cut down in size for installation)
  • Page 7: Preparations For Installing The Window Kit

    Please follow the installation instructions carefully to avoid personal injury or damage. Window Kit Installation Instructions Cut the foam seal B to the proper length and attach it to the windowsill. Attach the window exhaust adapter C to the window panel inside opening. Edgestar Portable Air Conditioner...
  • Page 8 Attach the window panel to the window panel If the inner width of the window is less than 28” (718 mm) wide: 1) Remove the adjustment panel from the window panel, and cut the window panel to the same width as the panel. 2) Open the window sash and place the window panel on the windowsill.
  • Page 9: Installation Of The Exhaust Hose

    B and C to the exhaust hose. Extend both ends of the exhaust hose and insert them into the window exhaust adapter A and B and turn them until they stop. Make sure they are securely attached. Edgestar Portable Air Conditioner...
  • Page 10: Notes About The Exhaust Hose

    Attach the window exhaust adapter A to the unit. Insert the two projections on the window exhaust adapter A into the two holes on the unit and firmly attach them to each other by sliding the adapter down until it clicks. To remove please make sure to push down on the two projections and lift up.
  • Page 11: Installation Of The Drain Hose

    Note: Drainage hose must be installed before using this unit to as not doing so can occur in a block in the drain and prevent the unit from functioning normally. Remove the drain cap from drain port. Edgestar Portable Air Conditioner...
  • Page 12: Draining The Unit

    Attach the drain hose clamp to the back panel of the air conditioner near the drain port with the screw. Attach one end of the drain hose to the drain port with the clip provided. Insert the rubber plug into the other end of the drain hose and secure clip provided.
  • Page 13: Installing The Filter

    1. Shut off the unit if it is on. In the rear of the unit pull the air filter grill from the side. 2. Place the carbon filter between the grille and the pre-filter. 3. Close the grille. Edgestar Portable Air Conditioner...
  • Page 14: Operating Instructions

    Operating Instructions Control Panel Overview On/Off Button Press the button once to manually turn the unit on. Press once more to turn the unit off. “+” / “-“ Button In COOL mode, press “-“once, the set temperature will decrease by 1° degree Fahrenheit. Continue to press to get to desired temperature.
  • Page 15: Directional Louvers

    Used to enable the sleep mode. Timer Used to enable the timer. Increases the set Increase temperature or the time when the Timer is enabled. Decreases the set Decrease temperature or time when the Timer is enabled. Edgestar Portable Air Conditioner...
  • Page 16 Installing the batteries CAUTION: Use only AAA batteries. Remove the batteries if the remote control will not be used for one month or longer. Do not attempt to recharge batteries not designed to be recharged. All batteries should be replaced at the same time. 1) Remove the cover on the back of the remote control.
  • Page 17: Timer

     Close all windows and doors.  Use the unit in a contained room. For example, a room with four walls and a ceiling, instead of a partitioned studio, or warehouse.  Make sure the unit is on a level surface. Edgestar Portable Air Conditioner...
  • Page 18: Maintenance

    2) Remove the activated carbon filter. replaced every 2-3 months or as 3) Use a vacuum cleaner or tap the filter lightly to remove loose needed. Contact EdgeStar dust and dirt, then rinse thoroughly under lukewarm running water retailers for replacement filters.
  • Page 19: Preparation For Storage

    2) Power off the unit, and clean or change the filters. 3) Unplug and carefully wind the power cord. 4) Remove the exhaust hose and duct connectors and keep them in a safe place. Edgestar Portable Air Conditioner...
  • Page 20: Troubleshooting

    Troubleshooting Follow the troubleshooting guide below to resolve common issues. Issue Possible Cause Solution My air conditioner is Unit is not receiving Make sure the unit is not functioning at all. power. plugged in to a grounded outlet. LCDI power cord is Press the Reset button tripped.
  • Page 21 The filter may be dusty Clean the filter and or blocked. replace it if needed. Dirty condenser coils. Carefully vacuum the coils clean. Obstructed air intake Remove anything or exhaust ports. blocking the ports. Edgestar Portable Air Conditioner...
  • Page 22 Issue Possible Cause Solution My air conditioner is Unit is not operating in Set the unit to be in not cooling at all. cooling mode. cooling mode, and lower the set temperature (pg. 13). The compressor is not The compressor may take up to 3 minutes to turn on, or longer if it is too warm.
  • Page 23: Error Codes

    Low pressure overcurrent Disconnect the power After 10 protection. minutes, turn the unit back on. If "E5" still exits, please contact EdgeStar customer service. Chassis is full of water. Pour out the water from inside the chassis through the drain plug.
  • Page 24: Specifications

    Specifications Description of product Portable Air Conditioner Model AP10002BL Voltage/Frequency AC 115V~60Hz Input Power 1120W Current 9.0 A Color Black Coolant R-410A, 18.3 oz. Timer 24 Hour Dimensions 13 3/8” x 30 11/16” x 15 1/2” WxHxD Weight 55.2 lbs.
  • Page 25: Edgestar Limited Warranty

    Once an EdgeStar authorized representative has confirmed that your product is defective and eligible for warranty service, the product must be returned to an EdgeStar authorized re- pair facility. EdgeStar is not responsible for damage resulting from shipper mishandling or improper packaging. Do not return a defective product to the place of purchase.
  • Page 26 Web: http://www.edgestar.com E-mail: service@edgestar.com Register your product, download owner’s manuals, access additional troubleshooting resources, and obtain more information on other great EdgeStar products on the web at: http://www.edgestar.com Product contents and specifications may change without notice. Copyright © 2014 Living Direct, Inc. All rights reserved.

Table of Contents