Table 12
POST Error Messages
Error-Code
610
500

POST related troubleshooting

Perform the following procedures when POST fails to run, displays error messages.
If the POST failure is during a routine boot up, check the following:
All external cables and power cables should be firmly plugged in.
The power outlet to the server should be connected and works correctly.
The server and monitor are both turned on. The bicolour status LED indicator on the front panel
must be lit up green.
The monitor's contrast and brightness settings are correct.
All internal cables are properly connected and all boards firmly seated.
The processor is fully seated in its socket on the system board.
The cooler assembly is properly installed on top of the processor.
All memory modules are properly installed.
If you have installed a PCI accessory board, verify that the board is firmly seated and any
switches or jumpers on the board are properly set. Refer to the documentation provided with the
accessory board.
All internal cabling and connections are in their proper order.
If you have changed any switches on the system board, verify that each is properly set.
Error Message
Temperature Violation
Detected!
Waiting 5 minutes for
system to cool.
Press ESC Key to resume
booting without waiting for
the system to cool.
Warning: Pressing ESC is
NOT recommended as
system may shutdown
unexpectedly.
Recheck Temperature in 300
second!
Unsupported Processor
Description / Corrective Action
Waiting 5 minutes for system to cool.
You can press ESC Key to resume booting without waiting for
the system to cool. But it is not recommended as system may
shutdown unexpectedly.
Recheck Temperature in 300 second!
System can't support this style CPU. You should change
another CPU.