Sign In
Upload
Manuals
Brands
Themis Manuals
Server
RES-32XR3/FIO
Themis RES-32XR3/FIO Manuals
Manuals and User Guides for Themis RES-32XR3/FIO. We have
2
Themis RES-32XR3/FIO manuals available for free PDF download: Installation Manual
Themis RES-32XR3/FIO Installation Manual (142 pages)
3RU 19” Rack-Mount Rugged Enterprise Server with X8DAH+-F Motherboard Configuration/Two Quad-Core 5500 or Quad/Six-Core 5600 Xeon CPUs
Brand:
Themis
| Category:
Server
| Size: 2 MB
Table of Contents
Safety Precautions
4
Warnings and Cautions
4
Safety Instructions
6
Grounding Methods
7
Table of Contents
9
Preface
21
Figure 1 Rugged Enterprise Server Model RES-32XR3/FIO
21
Table 1 RES-X2Xr3 Manual Matrix (AC and DC Power Supplies)
22
Table 2 RES-X2Xr3S / RES-X1Xr3 17" Chassis Manual Matrix (AC and DC Power Supplies)
23
Table 3 RES-X2Xr3/Fio 16" Chassis Manual Matrix (AC and DC Power Supplies)
24
Figure 1-1 RES-32XR3/FIO
27
1 Overview and Specifications
27
Overview
27
Table 1-2 RES-32XR3/FIO Major Features
28
Table 1-1 RES-32XR3/FIO Motherboard Options
28
Figure 1-2 X8DAH+-F Motherboard Block Diagram
29
Figure 1-3 External Features of RES-32XR3/FIO (Front)
30
System Leds and I/O Connectors
31
Table 1-3 Specifications of the RES-32XR3/FIO
31
Figure 1-4 Major Components of RES-32XR3/FIO (Open Top View)
32
Figure 1-5 RES-32XR3/FIO System Leds and I/O Connectors1
33
Table 1-4 System Leds
34
Table 1-5 I/O Connectors
35
Table 1-6 RES-32XR3/FIO General Specifications
41
Table 1-7 RES-32XR3/FIO Electrical Specifications
42
Electrostatic Discharge
43
Environmental
43
Output Voltage
43
Shock
43
Accessory Kit
44
Packaging and Shipping
44
Rack-Mount Slides (Optional)
45
Electrical
42
System Power
42
Chipset Overview
36
Features of the 5500/5600 Processor and the 5520 Chipset
36
PC Health Monitoring
37
Fan Status Monitor with Firmware Control
37
Environmental Temperature Control
37
CPU Fan Auto-Off in Sleep Mode
38
System Resource Alert
38
Special Features
37
Recovery from AC Power Loss
37
ACPI Features
38
Slow Blinking LED for Suspend-State Indicator
39
Main Switch Override Mechanism
39
Power Supply
39
Overview of the Winbond WPCM450 Controller
40
Super I/O
40
Specifications
41
General
41
Table 1-8 Approximate Weights of the RES Series
45
2 Installation and Operation
47
Installation Procedures
47
Remove Protective Top Cover
47
Figure 2-1 Remove the RES-32XR3/FIO Protective Access Cover
48
Memory Modules
49
Figure 2-2 Remove the Air-Flow Deflector Screws
50
Installation
50
Figure 2-3 Memory Module Slot Locations
51
Figure 2-7 the RES-32XR3/FIO Lithium Battery and Socket
54
Figure 2-10 the RES-32XR3/FIO 120-MM Fans
57
Power Supply
58
Removing a Power Supply
58
Installing a Power Supply
59
Figure 2-12 Right Rack-Mount Bracket
60
Mounting Brackets
60
Rack Mounts
60
Figure 2-13 AC Power Socket and LED on the RES-32XR3/FIO
61
Operation
61
Plugging in the AC Power Cords
61
Rack-Mount Slides (Optional)
61
Configuration
62
Figure 2-14 System Power Button and LED on the RES-32XR3/FIO Front
62
Getting Started
62
Linux Installation
62
Turning the System on
62
Turning the System off
63
Installing a Lithium Battery
55
SATA Storage Drive
55
Storage Drive Removal
55
Storage Drive Installation
56
Removable 120-MM Fan
57
Removing and Installing a 120-MM Fan
57
PCI Cards
53
Installing Cards
53
Lithium Battery
54
Removing the Lithium Battery
54
3 BIOS Setup Utility
65
Introduction
65
Starting BIOS Setup Utility
65
How to Change the Configuration Data
66
Starting the Setup Utility
66
Figure 3-1 Main BIOS Setup Screen
67
Figure 3-2 Advanced Settings
69
Figure 3-3 Security Settings
94
Boot Sector Virus Protection
95
Change User Password (Available When a User Password Is Installed)
95
Clear User Password (Available Only When User Password Is Installed)
95
Password Check (Available When a Password Is Installed)
95
User Access Level
95
Figure 3-4 Boot Settings
96
CD/DVD Drives
97
Removable Drives
97
Figure 3-5 Exit Options
98
Discard Changes
99
Load Fail-Safe Defaults
99
Load Optimal Defaults
99
Addon ROM Display Mode
70
Bootup Num-Lock
70
Hit 'Del' Message Display
70
Interrupt 19 Capture
70
PS/2 Mouse Support
70
Restore on AC Power Loss
70
Wait for 'F1' if Error
70
Watch Dog Function
70
Memory Frequency
74
Memory Mode
74
QPI Frequency
74
QPI L0S and L1
74
Demand Scrubbing
75
Patrol Scrubbing
75
Throttling - Closed Loop / Throttling - Open Loop
75
HDA Controller
76
Intel VT-D
76
SR-IOV Support
76
Active State Power Management
77
Ide/Floppy Configuration
77
Floppy a
78
IDE Detect Timeout (Sec)
78
Primary IDE Master/Slave, Secondary IDE Master/Slave, Third IDE Master, and Fourth IDE Master
78
SATA#1 Configuration
78
Pio Mode
79
Dma Mode
80
Intel I/OAT
77
Legacy USB Support
77
NUMA Support
77
Route Port 80H Cycles to
77
USB 2.0 Controller
77
USB Functions
77
Pci/Pnp Configuration
81
Clear NVRAM
81
PCI IDE Busmaster
81
PCI Latency Timer
81
PCI-E I/O Performance
81
Plug & Play os
81
Boot Graphics Adapter Priority
82
Load Onboard LAN1 Option Rom/Load Onboard LAN2 Option ROM
82
Onboard LAN Option ROM Select
82
PCI-E Slot 1 X8, PCI-E Slot 2 X16, PCI-E Slot 3 X8
82
Super IO Device Configuration
82
Serial Port1 Address/Serial Port2 Address
82
Flow Control
83
Onboard Floppy Controller
83
Redirection after BIOS POST
83
Remote Access
83
Remote Access Configuration
83
Serial Port Mode
83
Serial Port Number
83
CPU Overheat Alarm
84
Hardware Health Monitor
84
Sredir Memory Display Delay
84
Terminal Type
84
VT-UTF8 Combo Key Support
84
CPU 1 Temperature/Cpu 2 Temperature/System Temperature
85
System Temperature
86
ACPI Configuration
87
High Performance Event Timer
87
PS2 KB/MS Wake up
87
USB Device Wakeup
87
Voltage Readings
87
ACPI APIC Support
88
ACPI Aware O/S
88
ACPI Version Features
88
Apic Acpi Sci Irq
88
Headless Mode
88
Suspend Mode
88
TCG/TPM (Trusted Platform Module) Support
88
Trusted Computing
88
IPMI Configuration
89
IPMI Firmware Revision
89
Clear BMC System Event Log
90
Set LAN Configuration
90
Status of BMC
90
View BMC System Event Log
90
Channel Number
91
Channel Number Status
91
IP Address Source
91
Mac Address
91
BMC Watch Dog Timer Action
92
PEF Support
92
SET PEF Configuration
92
Clear Event Log
93
Event Log Configuration
93
Mark All Events as Read
93
PCI Error Log
93
View Event Log
93
Change Supervisor Password
94
Security Settings
94
Supervisor Password
94
User Password
94
Boot Configuration
96
Boot Device Priority
96
Storage Drives
96
Discard Changes and Exit
98
Exit Options
98
Save Changes and Exit
98
BIOS Recovery
99
Boot Sector Recovery from a Serial Port ("Serial Flash")
100
Boot Sector Recovery from a USB Device
100
Boot Sector Recovery from an IDE CD-ROM
100
Requirements
100
BIOS Error Beep Codes
104
Main Setup
67
System Time/System Date
67
Processor
68
Supermicro X8DAH
68
System Memory
68
Advanced Setup Configurations
69
Boot Features
69
Quick Boot
69
Quiet Boot
69
Processor and Clock Options
71
Adjacent Cache Line Prefetch (Available When Supported by the CPU)
71
Clock Spread Spectrum
71
CPU Ratio
71
Hardware Prefetcher (Available When Supported by the CPU)
71
Ratio CMOS Setting (Available When the Item-CPU Ratio Is Set to Manual)
71
Active Processor Cores
72
Execute-Disable Bit Capability (Available When Supported by the os and the CPU)
72
Intel® EIST Technology
72
Intel® Virtualization Technology (Available When Supported by the CPU)
72
Simultaneous Multi-Threading (Available When Supported by the CPU)
72
C-State Package Limit Setting (Available When Intel® C-State Tech Is Enabled)
73
C1 Auto Demotion
73
C1E Support
73
C3 Auto Demotion
73
Intel® C-STATE Tech
73
DCA Technology
73
DCA Prefetch Delay
73
Advanced Chipset Control
74
QPI Links Speed
74
Figure 3-6 AMI_FLSH Hyperterminal
102
Figure 3-8 Flash Recovery
103
Figure 3-7 ROM File Extraction
103
Appendix A. Connector Pinouts
105
PS/2 Keyboard and Mouse
105
USB Ports
106
Serial Port
106
VGA Display Port
107
Table A-4 RES-32XR3/FIO VGA Connector-Pin Signals
107
Gigabit Ethernet LAN Ports
108
IPMI Dedicated LAN Port
108
Figure
108
Figure A-4 Ethernet Connector, Type RJ45
108
Table A-5 RJ45 Ethernet Pinout Signals
108
Figure B-1 Screw Locations for Rack-Mount Slides
109
Appendix B. Rack-Mount Slide Installation
109
Figure B-2 RES-32XR3/FIO Rack-Mount Slide Installation
111
Appendix C. Red hat Enterprise Linux 5 Installation
113
Introduction
113
Figure C-2 Skip Key
114
Figure C-3 Welcome Screen
115
Figure C-4 Language Selection
115
Figure C-5 Selecting Layout Type
116
Figure C-6 Enter Installation Number
116
Figure C-7 Partitioning
117
Figure C-8 Reviewing Option
118
C.2.9 Step 9
119
Figure C-9 Creating a Custom Layout
119
C.2.10 Step 10
120
Figure C-10 Setting up Boot Loader
120
Figure C-11 Master Boot Record (MBR
121
Figure C-12 Network Devices List
122
C.2.13 Step 13
123
Figure C-13 Edit Interface Pop-Up Screen
123
C.2.14 Step 14
124
Figure C-14 Selecting Time Zone
124
Figure C-15 Setting up Root Account and Password
125
C.2.16 Step 16
126
Figure C-16 Package Installation Default Screen
126
C.2.17 Step 17
127
Figure C-17 Optional Packages
127
C.2.18 Step 18
128
Figure C-18 Option to Review or Continue
128
Figure C-19 Installation Begins
128
Step 19
128
Figure C-20 Installation Is Complete
129
Step 20
129
Figure C-21 Login Screen
130
Step 21
130
Step 22
130
Figure C-1 Power on after Linux DVD Is Inserted into Drive
114
C.2.8 Step 8
118
Installation
114
Step 1
114
Step 2
114
C.2.7 Step 7
117
Appendix D. Optional Remote On/Off Switch
131
Remote On/Off Configuration
131
Remote Only Configuration
132
Ordering the Remote On/Off Switch
132
Appendix E. Re-Packing Instructions
133
Re-Packaging for Shipment
133
Packing Components
133
Instructions for Re-Packing
134
Packaging Components
134
Figure E-2 Order of Assembly
135
Index
137
Advertisement
Themis RES-32XR3/FIO Installation Manual (142 pages)
2RU 19" x17" Rack-Mount Rugged Enterprise Server with X8SAX Motherboard Configuration/One Quad-Core 5500 or Quad/Six-Core 5600 Xeon CPU
Brand:
Themis
| Category:
Server
| Size: 2 MB
Table of Contents
Safety Precautions
4
Warnings and Cautions
4
Safety Instructions
6
Grounding Methods
7
Table of Contents
9
Preface
21
Figure 1 Rugged Enterprise Server Model RES-21XR3
21
Figure 1-1 RES-21XR3
22
Table 1 RES-X2Xr3-S / RES-X1Xr3 17" Chassis Manual Matrix (AC and DC Power Supplies)
22
Table 2 RES-X2Xr3 20" Chassis Manual Matrix (AC and DC Power Supplies)
23
Table 3 Front I/O 16" Chassis Manual Matrix (AC and DC Power Supplies)
24
1 Overview and Specifications
27
Overview
27
Table 1-1 RES-21XR3 for X8SAX Motherboard Options
28
Table 1-2 Major Features of the RES-21XR3
28
Figure 1-2 X8SAX Motherboard Block Diagram
29
Figure 1-3 External Features of RES-21XR3 for X8SAX (Front and Rear)
30
System Leds and I/O Connectors
31
Figure 1-4 Major Components of RES-21XR3 for X8SAX (Top View)
32
Figure 1-5 RES-21XR3 System Leds and I/O Connectors
33
Table 1-3 System Leds
34
Table 1-4 I/O Connectors
35
Chipset Overview
36
Features of the LGA 1366 Processor and the X58
36
PC Health Monitoring
36
Recovery from Main Power Loss
36
Onboard Voltage Monitoring
37
Fan Status Monitor with Firmware Control
37
CPU Overheat LED and Control
37
Power Configuration Settings
37
Slow Blinking LED for Suspend-State Indicator
37
BIOS Support for USB Keyboard
38
Main Switch Override Mechanism
38
Wake-On-LAN (WOL)
38
Super I/O
38
Specifications
40
General
40
Electrical
41
Output Voltage
41
System Power
41
Environmental
42
Electrostatic Discharge
42
Figure 1-6 RES-21XR3 with Front Sound Baffle Installed (Front View)
42
Noise
42
Shock
42
Figure 1-7 RES-21XR3 with Rear Sound Baffle Installed (Rear View)
43
Packaging and Shipping
44
Accessory Kit
44
Rack-Mount Slides (Optional)
45
2 Installation and Operation
47
Installation Procedures
47
Remove Protective Top Cover
47
Figure 2-1 Remove the RES-21XR3 Protective Access Cover
48
Memory Modules
49
Figure 2-2 Remove the Air-Flow Deflector Screws
51
Installation
51
Figure 2-3 Memory Module Slot Locations
52
PCI Cards
53
Figure 2-4 Memory Module Removal
53
Figure 2-5 RES-21XR3 for X8SAX PCI Card Installation
54
Figure 2-6 PCI Card Clamp
54
Installing Cards
54
Lithium Battery
55
Removing the Lithium Battery
55
Installing a Lithium Battery
56
SAS/SATA Storage Drive
56
Figure 2-7 the RES-21XR3 for X8SAX Lithium Battery and Socket
56
Figure 2-8 Opening the RES-21XR3 for X8SAX Front Bezel Doors
57
Figure 2-9 Unlocking the RES-21XR3 Storage Drives (Front Doors Open)
57
Opening the RES-21XR3 Front Doors
57
Storage-Drive Removal
58
Figure 2-10 RES-21XR3 Storage Drive Removal
59
Storage-Drive Installation
59
Hot-Swappable 80-MM Fan
60
Figure 2-11 the RES-21XR3 80-MM Fans
60
Removing and Installing a 80-MM Fan
60
Power Supply
61
Removing a Power Supply
61
Figure 2-12 the RES-21XR3 Power Supply Locking Mechanism
62
Installing a Power Supply
62
Rack Mounts
63
Mounting Brackets
63
Rack-Mount Slides (Optional)
63
Figure 2-13 Right Rack-Mount Bracket
63
Operation
64
Plugging in the AC Power Cords
64
Turning the System on
64
Figure 2-14 AC Power Socket and LED on the RES-21XR3 Rear
64
Getting Started
65
Configuration
65
Figure 2-15 System Power Button and LED on the RES-21XR3 Front
65
Linux Installation
65
Turning the System off
66
3 BIOS Setup Utility
67
Introduction
67
Starting BIOS Setup Utility
67
How to Change the Configuration Data
68
Starting the Setup Utility
68
Main BIOS Setup
69
System Time/System Date
69
Figure 3-1 Main BIOS Setup Screen
69
Ambios
70
Processor
70
System Memory
70
Advanced Setup Configurations
71
Boot Features
71
Figure 3-2 Advanced Settings
71
Quick Boot
71
Quiet Boot
71
Addon ROM Display Mode
72
Bootup Num-Lock
72
Hit 'Del' Message Display
72
Power Button Function
72
PS/2 Mouse Support
72
Restore on AC Power Loss
72
Wait for 'F1' if Error
72
Watch Dog Function
72
EUP Support
73
Interrupt 19 Capture
73
Processor and Clock Options
73
Clock Spread Spectrum
73
CPU Ratio
73
Adjacent Cache Line Prefetch (Available When Supported by the CPU)
74
Execute-Disable Bit Capability (Available When Supported by the os and the CPU)
74
Hardware Prefetcher (Available When Supported by the CPU)
74
Intel® Virtualization Technology (Available When Supported by the CPU)
74
MPS and ACPI MADT Ordering
74
Active Processor Cores
75
C-STATE Tech
75
C1E Support
75
Intel AES-NI (When Supported by the CPU)
75
Intel® EIST Technology
75
Intel® Turboboost Technology (Available When Intel® EIST Technology Is Enabled)
75
Simultaneous Multi-Threading (Available When Supported by the CPU)
75
C-State Package Limit Setting
76
C1 Auto Demotion
76
C3 Auto Demotion
76
ACPI T State
76
DCA Technology
76
DCA Prefetch Delay
76
Advanced Chipset Control
76
QPI & IMC Configuration
77
QPI Links Speed
77
QPI Frequency
77
QPI L0S and L1
77
Memory Frequency
77
Memory Mode
77
Demand Scrubbing
78
Patrol Scrubbing
78
Throttling - Closed Loop
78
HDA Controller
78
Intel VT-D
78
SR-IOV Support
79
Intel I/OAT
79
Active State Power Management
79
Route Port 80H Cycles to
79
Extend PCI Hole
79
USB Functions
79
USB 2.0 Controller
79
Legacy USB Support
80
IDE / Floppy Configuration
80
Floppy a
80
SATA#1 Configuration
80
SATA#2 Configuration
80
IDE Detect Timeout (Seconds)
80
Primary IDE Master/Slave, Secondary IDE Master/Slave, Third IDE Master, and Fourth IDE Master
81
Dma Mode
82
Pci/Pnp Configuration
83
Clear NVRAM
83
Plug & Play os
83
PCI Latency Timer
83
PCIX Slot Frequency
84
Boot Graphics Adapter Priority
84
Load Onboard LAN1/LAN2 Option ROM
84
PCI IDE Busmaster
84
PCI Slot 1-PCI Slot 6
84
Pcie I/O Performance
84
ROM Scan Ordering
84
Onboard Floppy Controller
85
Remote Access
85
Remote Access Configuration
85
Serial Port 1 Address / Serial Port 2 Address
85
Super IO Device Configuration
85
Hardware Health Configuration
86
CPU Overheat Alarm
87
CPU Temperature
87
Fan Speed Control Modes
89
Fan1-Fan 6 Reading
89
IOH Temperature
89
System Temperature
89
ACPI Aware O/S
90
ACPI Configuration
90
High Performance Event Timer
90
Suspend Mode
90
USB Device Wakeup from S3/S4
90
Voltage Reading
90
ACPI APIC Support
91
ACPI Version Features
91
AMI OEMB Table
91
Apic Acpi Sci Irq
91
Clear Event Log
91
Event Log Configuration
91
Headless Mode
91
Mark All Events as Read
91
View Event Log
91
Memory ECC Error Log
92
Pcie Error Log
92
Security Settings
92
Figure 3-3 Security Settings
92
Supervisor Password
92
Change Supervisor Password
93
Change User Password
93
User Access Level (When Supervisor Password Is Set)
93
User Password
93
Boot Sector Virus Protection
94
Boot Configuration
94
Boot Device Priority
94
Figure 3-4 Boot Settings
94
CD/DVD Drives
95
Hard Disk/Solid State Drives
95
Removable Drives
95
Exit Options
95
Figure 3-5 Exit Options
95
Discard Changes
96
Discard Changes and Exit
96
Load Fail-Safe Defaults
96
Load Optimal Defaults
96
Save Changes and Exit
96
BIOS Recovery
97
(Recommended Method)
97
Part 1-Boot Sector Recovery Process
97
Recovery Process from a USB Device
97
Figure 3-6 Flash Recovery
98
Part 2-BIOS Reprogramming (Re-Flashing)
98
Recovery from an IDE/SATA ATAPI Disc Drive
98
Appendix A. Connector Pinouts
101
PS/2 Keyboard and Mouse
101
USB Ports
102
Gigabit Ethernet LAN Ports
102
Figure A-1 USB Connector Pinout
102
Figure A-2 Ethernet Connector, Type RJ45
102
Figure
102
High Definition Audio
103
Figure A-3 High Definition Audio Ports
103
S/Pdif_Out Connector
104
Figure A-4 S/Pdif_Out Connector
104
Table A-5 S/PDIF Bottom Component Pin Definition
105
Appendix B. Rack-Mount Slide Installation
107
Figure B-1 Screw Locations for Rack-Mount Slides
107
Appendix C. Red hat Enterprise Linux 5 Installation
111
Introduction
111
Installation
112
Step 1
112
Step 2
112
Figure C-1 Power on after Linux DVD Is Inserted into Drive
112
Figure C-2 Skip Key
112
Figure C-3 Welcome Screen
113
Figure C-4 Language Selection
113
C.2.3 Step 3
113
Step 6
114
Figure C-5 Selecting Layout Type
114
Figure C-6 Enter Installation Number
114
C.2.5 Step 5
114
Step 7
115
Figure C-7 Partitioning
115
C.2.7 Step 7
115
Step 8
116
Figure C-8 Reviewing Option
116
C.2.8 Step 8
116
Step 9
117
Figure C-9 Creating a Custom Layout
117
C.2.9 Step 9
117
Figure C-10 Setting up Boot Loader
118
C.2.10 Step 10
118
Figure C-11 Master Boot Record (MBR
119
Figure C-12 Network Devices List
120
Figure C-13 Edit Interface Pop-Up Screen
121
Figure C-14 Selecting Time Zone
122
Figure C-15 Setting up Root Account and Password
123
Figure C-16 Package Installation Default Screen
124
Figure C-17 Optional Packages
125
Step 19
126
Figure C-18 Option to Review or Continue
126
Figure C-19 Installation Begins
126
C.2.18 Step 18
126
Step 20
127
Step 21
128
Step 22
128
Appendix D. Optional Remote On/Off Switch
129
Remote On/Off Configuration
129
Remote Only Configuration
129
Remote On/Off Switch Module
129
Figure
129
Ordering the Remote On/Off Switch
130
Appendix E. Re-Packing Instructions
131
Re-Packaging for Shipment
131
Packing Components
131
Instructions for Re-Packing
132
Packaging Components
132
Figure
132
Index
135
Reader Comment Card
142
Advertisement
Related Products
Themis RES - 32XR3
Themis RES-32XR3-S
Themis RES-32XEL
Themis RES-32DCX
Themis RES-31XR3
Themis RES-XR4-1U
Themis RES-22DCX
Themis RES-22XR3
Themis RES-12XR3
Themis RES-21XR3
Themis Categories
Server
Barcode Reader
Motherboard
Laboratory Equipment
Video Card
More Themis Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL