Sign In
Upload
Manuals
Brands
Emerson Manuals
UPS
Liebert NX 480V
Emerson Liebert NX 480V Manuals
Manuals and User Guides for Emerson Liebert NX 480V. We have
1
Emerson Liebert NX 480V manual available for free PDF download: User Manual
Emerson Liebert NX 480V User Manual (108 pages)
40-120kVA, 480V, 60Hz
Brand:
Emerson
| Category:
UPS
| Size: 9.69 MB
Table of Contents
Table of Contents
3
Instructions
9
Save These Instructions
9
Glossary of Symbols
11
1 Installation
12
External Inspections
12
Internal Inspections
13
Storing for Delayed Installation
13
Preliminary Checks
13
Identification
13
UPS Location
13
Positioning the UPS
13
Environmental Considerations
13
Special Considerations for Parallel Systems
14
Considerations in Moving the Liebert NX
14
Mechanical Considerations
14
Clearances
15
Floor Installation
15
Cable Entry
15
Optional Cabinets
15
Figure 1 Cabinet Arrangement-Liebert NX Units and Battery Cabinets
16
Figure 2 Cabinet Arrangement-Liebert NX Units, Battery Cabinets and Liebert FPC
17
2 Electrical Connections
18
Power Cabling
18
Cable Rating
18
UPS Input Configuration
19
Cabling Guidelines
19
Figure 3 Single Module Block Diagram-Dual Input Configuration
19
Cable Connections
20
Figure 4 Input and Output Busbars
20
Safety Ground
21
Protective Devices
21
Cabling Procedure
22
Control Cables
23
Monitor Board Features
23
Figure 5 Monitor Board U2
23
Dry Contacts
24
Figure 6 Auxiliary Terminal Block Detail (Monitoring Board)
24
Figure 7 Input Dry Contacts
25
Input Dry Contacts
25
Maintenance Bypass Cabinet Interface
25
Table 1 Input Dry Contacts at X3
25
Table 2 Maintenance Bypass Cabinet Interface
25
BCB Control Interface
26
Figure 8 Jumper Connection for BCB Interface Without a Battery Interface Board
26
Table 3
26
Figure 9 Output Dry Contacts and EPO Wiring for Firmware before M170
27
Output Dry Contacts
27
Table 4 Output Dry Contact Relays
27
EPO Input-Optional
28
Figure 10 EPO Wiring
28
Table 5 EPO Input Contact Relays
28
3 Battery Installation
29
Introduction
29
Safety
29
External Battery Cabinet Installation
30
Battery Cabinets
30
Figure 11 Battery Cabinet
30
Connecting the Batteries
31
Installation Considerations
31
Figure 12 Battery Cabinet-Details
31
Connecting the Battery Cabinet to the UPS
32
Non-Standard Batteries
32
BCB Shunt Trip
32
Figure 13 Battery Tray and Supports
32
Alber Monitoring System-Optional
33
4 Options
34
Load Bus Synchronization
34
Performance Requirements
34
LBS Cable and Settings
34
Figure 14 Load Bus Synchronization Cable Connection in Single Module Systems
34
Configuring Parallel System Operation
35
General
35
Features of Parallel System
35
Figure 15 Load Bus Synchronization Cable Connection with Multi-Module Systems
35
Operating Principles
36
Operation Modes Summary
36
Installing Parallel System
36
Figure 16 Parallel System Block Diagram
36
Cabinet Installation
37
Conditions for Parallel System
37
Parallel Control Cables
37
Power Cables
37
Preliminary Checks
37
Figure 17 Connecting System Parallel Control Cables
38
Figure 18 Auxiliary Dry Contact Cables for Output Breaker in Multi-Module System
38
Figure 19 Dry Contacts, Multiple UPS Modules with Distribution Panel
39
Emergency Power off (EPO)
40
Figure 20 Connecting EPO Push Button
40
5 Ups Specifications
41
Conformity and Standards
41
UPS Environmental
41
UPS Mechanical Characteristics
41
Table 6 Environmental Characteristics
41
UPS Electrical Characteristics
42
Table 8 UPS Terminal
42
Input Rectifier
43
Rectifier Input Power
43
Table 10 Input Voltage Window with Derating
43
Table 11 Liebert Approved Replacement Batteries
43
Table 8
43
Table 9 Rectifier Input Power
43
Bypass Input
44
DC Intermediate Circuit
44
Inverter Output
44
Table 12 DC Intermediate Circuit
44
Table 13 Inverter Output
44
Table 14 Bypass Input
44
6 Installation Drawings
45
Figure 21 Dimensional View- Front and Left Side Views
45
Figure 22 Dimensions Continued-Top and Bottom Views
46
Figure 23 Main Components-Typical Unit
46
Figure 24 Cable Connections
47
Figure 25 Outline Drawing, 33" Battery Power Pack System, Single Cabinet
48
Figure 26 Terminal Details, 33" Battery Power Pack System, Single Cabinet Liebert NX
49
Figure 27 Battery Connections
50
Figure 28 Battery Cabinet Interconnection
51
Figure 29 Outline Drawing, Liebert NX480V, 80-120Kva Type E and E2 Parallel Cabinet
52
Figure 30 Outline Drawing, Liebert NX480V, 80-120Kva Type E1 Parallel Cabinet
53
Figure 31 Main Component Location Drawing Liebert NX 480V, Type E Parallel Cabinet
54
Figure 32 Main Component Location Drawing Liebert NX 480V, Type E1 Parallel Cabinet
55
Figure 33 Main Component Location Drawing Liebert NX 480V, Type E2 Parallel Cabinet
56
Figure 34 Lineup Detail-Parallel Type E Connection to Liebert NX
57
Figure 35 Lineup Detail-Parallel Type E1 Connection to Liebert NX
58
Figure 36 Lineup Detail-Parallel Type E2 Connection to Liebert NX
59
Figure 37 Line-Up Detail, Bolt Together Description, 40-120 Kva Liebert NX
60
7 Operation
61
General Description
61
Figure 38 Single Module Block Diagram (Dual Input Configuration)
61
Bypass Supplies
62
Operating Modes
62
8 Operator Ontrol and Display Panel
64
O Perator C Ontrol and D Isplay P Anel
64
Operator Control Panel
64
Display Panel Layout
64
Figure 39 Overview of Control Panel
64
Figure 40 Detailed View of Control Panel
65
MIMIC Display Indicators
66
Figure 41 MIMIC Display Indicators Location
66
Table 15 MIMIC Display Status Indicators
66
Control Buttons
67
Figure 42 Location of Control Buttons
67
Table 16 Control Buttons
67
Audible Buzzer
68
LCD Overview
68
Figure 43 Buzzer Location
68
Figure 44 Sections of the LCD
68
Navigation Keys
69
UPS System Information
69
Table 17 Icons for Navigation Keys
69
Table 18 Description of Items in UPS System Window
69
LCD Menus and Data Items
70
Figure 45 Menu Tree
70
Table 19 Descriptions of UPS Menus and Data Window Items
71
Language Selection
72
Figure 46 Language Selection
72
Current Date and Time
73
Figure 47 Set Date and Time
73
UPS Status Messages
74
Figure 48 Current Status and History Log Records
74
Types of LCD Screens
75
Opening Display
75
8.12.2 Default Screen
75
Figure 49 Opening Display
75
Figure 50 Default Screen
75
8.12.3 UPS Help Screen
76
8.12.4 Screen Saver Window
76
Figure 51 Help Screen
76
Figure 52 Screen Saver Window
76
Pop-Up Windows
77
8.13.1 from Bypass to Inverter Mode with Power Interruption
77
8.13.2 from Inverter to Bypass Mode with Interruption
77
8.13.3 System Self-Test
77
8.13.4 Battery Capacity Test Confirmation
77
8.13.5 Battery Self-Test Aborted, Condition Not Met
77
8.13.6 Battery Refresh Charge Aborted, Condition Not Met
77
9 Operating Instructions
78
Liebert NX Operating Modes
78
Table 20 UPS Operating Modes
78
Circuit Breakers
79
Figure 53 Circuit Breakers
79
UPS Startup
80
Startup Procedure
80
Verify Switching between Operation Modes
81
Maintenance Bypass Procedure and Powering down the UPS
82
Auto Restart
83
Emergency Shutdown with EPO
83
Reset after Shutdown for Emergency Stop (EPO Action) or Other Conditions
83
Battery Protection
84
Battery Undervoltage Pre-Warning
84
Battery End-Of-Discharge (EOD) Protection
84
Multi-Module System Procedures
84
Isolating One Module in a Multi-Module System
84
And Optional Output / Bypass Distribution Panel
85
Figure 54 Typical Parallel System Block Diagram with Common Input Supply, with Separate Batteries
85
Inserting One Module into a Multi-Module System
86
Shutdown Procedure-Complete UPS and Load Shutdown
87
Commissioning a Parallel System
87
Parallel System Start up
88
10 Options
89
Communication and Other User Terminals
89
10.1.1 Analog Input Interface
89
10.1.2 Power Output
89
10.1.3 Liebert Intellislot Communication
89
Figure 55 Monitoring Board (U2) Auxiliary Terminal Block Detail
89
10.1.4 Communication and Monitoring
90
Table 21 Liebert NX Communication Options
90
10.1.5 Configuring Baud Rates
91
Figure 56 Liebert Intellislot Web Card Display
92
Table 22 Relay Card Pin Configuration
93
Table 23 Relay Card Jumper Configuration
93
Figure 57 Multiport 4 Card Pin Assignment
94
LBS Mode-Load Bus Synchronization
95
10.2.1 Remote Alarm Monitor
95
Replacing Dust Filters
95
Figure 58 Dust Filter Replacement
95
11 Specifications and Technical Data
96
Lug Size and Torque Requirements
96
Cable Lengths: Floor to Connection Point Inside UPS
96
Table 24 Torque Specifications
96
Table 25 Battery Torque Rating
96
Table 26 Distance to Connection Points on the Liebert NX UPS
97
Table 27 Parallel System Current Table
97
Cable Size and Tightening Torques
98
Table 28 External Cabinet Dimensions, Including Side Panels
98
Table 29 Lead/Lag Ratings
98
Table 30 Cable Size Tightening Torque at Liebert NX 40Kva UPS Terminals
98
Table 31 Cable Size Tightening Torque at Liebert NX 60Kva UPS Terminals
98
Table 32 Cable Size Tightening Torque at Liebert NX 80Kva UPS Terminals
99
Table 33 Cable Size Tightening Torque at Liebert NX 100Kva UPS Terminals
99
Table 34 Cable Size Tightening Torque at Liebert NX 120Kva UPS Terminals
99
Battery Run Times
100
Table 35 Estimated Battery Run Time, Minutes
100
Messages
101
Table 36 UPS Status Messages
101
Advertisement
Advertisement
Related Products
Emerson Liebert NX 400V
Emerson Liebert NX 40 kVA
Emerson Liebert NX 40kVA
Emerson Liebert NXL 400 kVA
Emerson Liebert NX 30kVA
Emerson Liebert NX 80kVA
Emerson Liebert NX 60kVA
Emerson Liebert NX 120kVA
Emerson Liebert NXL 500 kVA
Emerson Liebert NXL 1100 kVA
Emerson Categories
Controller
Control Unit
Transmitter
Measuring Instruments
Fan
More Emerson Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL