Sign In
Upload
Manuals
Brands
Daikin Manuals
Air Conditioner
FMCQ100A7VEB
Daikin FMCQ100A7VEB Manuals
Manuals and User Guides for Daikin FMCQ100A7VEB. We have
3
Daikin FMCQ100A7VEB manuals available for free PDF download: Service Manual, Installation And Operation Manual
Daikin FMCQ100A7VEB Service Manual (502 pages)
SkyAir series Service Diagnosis
Brand:
Daikin
| Category:
Air Conditioner
| Size: 2.95 MB
Table of Contents
Table of Contents
2
1 List of Applicable Models
8
R-FU Series
8
R-GA Series
9
R-G Series
9
R-KU Series
10
R-LU Series
11
2 Symptom-Based Troubleshooting
36
2.1 Overview
36
Applicable Model
38
Supposed Causes
38
2.2 Equipment Does Not Operate
38
Troubleshooting
39
Indoor Unit Fan Operates, but Compressor Does Not Operate
40
Cooling / Heating Operation Starts but Stops Immediately
43
After Unit Shuts Down, It Cannot be Restarted for a While
45
Equipment Operates but Does Not Provide Cooling
48
Equipment Operates but Does Not Provide Heating
51
Equipment Discharges White Mist
54
Equipment Produces Loud Noise or Vibration
56
2.10 Equipment Discharges Dust
59
Remote Controller LCD Displays "88
60
3 Troubleshooting by Remote Controller
61
Procedure of Self-Diagnosis by Remote Controller
61
Wired Remote Controller
62
Hecking an Error or Warning
62
Wireless Remote Controller
63
Taking Corrective Action
63
3.2 Error Codes and Description
66
Outdoor Unit, System
69
Inverter Series
71
3.3 Detailed Error Codes
80
A0 Error of External Protection Device
86
Method of Error Detection
86
Error Decision Conditions
86
A1 Indoor Unit PCB Abnormality
88
A3 Drain Water Level System Abnormality
90
A6 Indoor Unit Fan Motor Abnormality
93
A6 Fan Motor (M1F) Lock, Overload
103
A7 Swing Flap Motor Abnormality / Lock
105
A8 Abnormal Power Supply Voltage
107
A9 Electronic Expansion Valve Coil (Y1E) Abnormality
109
AF Drain System Abnormality
112
AF Drain Level above Limit
114
AJ Capacity Setting Abnormality
115
Remote Controller Display
117
C1 Transmission Error (between Indoor Unit PCB and Fan PCB)
122
C1 Transmission Error (between Indoor Unit PCB and Adaptor PCB)
125
C4, C5, C9 Thermistor Abnormality
128
C6 Defective Combination (between Indoor Unit PCB and Fan PCB)
130
CC Humidity Sensor System Abnormality
132
CJ Remote Controller Thermistor Abnormality
135
E0 Actuation of Safety Device
137
E0 Activation of Outdoor Unit Protection Device
145
E1 Outdoor Unit PCB Abnormality
147
E3 High Pressure System Abnormality
150
E3 Abnormally High Pressure Level (HPS)
155
E3 High Pressure Abnormality (HPS)
157
E3 Actuation of High Pressure Switch
160
E4 Low Pressure System Abnormality
169
E4 Actuation of Pressure Sensor
171
E4 Actuation of Low Pressure Sensor
175
E4 Low Pressure System Abnormality
180
E5 Compressor Motor Lock
183
E6 Compressor Overcurrent
188
Approximate Input Current Value
190
E7 Outdoor Unit Fan Motor Abnormality
191
E9 Electronic Expansion Valve Abnormality
203
E9 Electronic Expansion Valve Coil Abnormality
207
F3 Discharge Pipe Temperature Abnormality
217
F3 Discharge Pipe Temperature Control
225
F6 Abnormal Heat Exchanging Temperature
227
F6 Refrigerant Overcharged
229
H3 High Pressure Switch Abnormality
231
H3 High Pressure Switch System Abnormality
236
H4 Low Pressure Sensor System Abnormality
238
H7 Outdoor Unit Fan Motor Signal Abnormality
242
H9, J3, J5, J6, J7, J8 Thermistor System Abnormality
244
H9 Outdoor Air Thermistor System Abnormality
246
J1 Pressure Sensor Abnormality
248
J2 Current Sensor System Abnormality
250
J3 Discharge Pipe Thermistor System Abnormality
252
J5 Suction Pipe Thermistor Abnormality
255
J6 Heat Exchanger Thermistor System Abnormality
257
J7 Liquid Pipe Thermistor Abnormality
259
J9 Subcooling Heat Exchanger Gas Pipe Thermistor Abnormality
261
JA High Pressure Sensor Abnormality
263
JC Suction Pipe Pressure Sensor Abnormality
266
L1 Outdoor Unit PCB Abnormality
268
L1 Outdoor Inverter PCB Abnormality
270
L1 Outdoor Unit PCB Abnormality
272
L4 Overcurrent of DC Output (Instantaneous)
275
L4 Radiation Fin Temperature Rise
277
Radiation Fin Temperature Detection Value
279
L5 Overcurrent of DC Output (Instantaneous)
285
L5 Momentary Overcurrent of Inverter Compressor
288
L5 Output Overcurrent Detection
291
L5 Inverter Compressor Abnormality
294
L5 Output Overcurrent Detection
297
(L8) Electronic Thermal Switch (Time Lag)
301
L8 Inverter Current Abnormality
304
L8 Inverter Compressor Overcurrent
307
L8 Electronic Thermal (Time Lag)
310
L9 Stall Prevention (Time Lag)
316
L9 Inverter Startup Error
318
LC Transmission Error between Inverter and Control PCB
324
LC Transmission Error (between Control PCB and Inverter PCB)
330
P1 Inverter Over-Ripple Protection
333
P1 Open Phase or Power Supply Voltage Imbalance
336
P4 Radiation Fin Thermistor Abnormality
338
P4 Radiation Fin Thermistor or Related Abnormality
342
PJ Defective Capacity Setting
343
PJ Error in Capacity Setting
345
PJ Field Setting Error after Replacing Main PCB or Defective Combination of PCB
346
PJ Defective Combination of Inverter and Fan Driver
348
PJ Defective Capacity Setting
350
U0 Refrigerant Shortage
354
U0 Low Pressure Drop Due to Refrigerant Shortage or Electronic Expansion Valve Failure
356
U0 Refrigerant Shortage
359
U1 Reverse Phase
365
U2 Insufficient Voltage
368
U2 Power Supply Voltage Abnormality
370
U2 Power Supply Insufficient or Instantaneous Failure
372
U2 Power Supply Voltage Abnormality
377
U3 Check Operation Is Not Executed
380
U4 or UF Transmission Error (between Indoor Unit and Outdoor Unit)
382
U4 Transmission Error between Indoor Unit and Outdoor Unit
388
U5 Transmission Error between Indoor Unit and Remote Controller
411
U7 Transmission Error between Outdoor Units
419
U8 Transmission Error between Main Remote Controller and Sub Remote Controller
422
U9 Transmission Error between Indoor and Outdoor Units in the same System
428
UA Defective Field Setting Switch
431
UA Improper Combination of Indoor and Outdoor Units, Indoor Units and Remote Controller
434
UA Field Setting Switch Abnormality
437
UA Field Setting Switch and Transmission Line Abnormality
440
UC Centralized Address Setting Error
444
UC Address Duplication of Centralized Controller
445
UE Transmission Error between Centralized Controller and Indoor Unit
446
UF Mis-Connection of Field Wiring
454
UF System Is Not Set yet
455
UF Transmission Error between Indoor and Outdoor Unit / Piping and Wiring Mismatch / Refrigerant Shortage
457
Outdoor Units
458
UF Transmission System Abnormality (between Indoor and Outdoor Units)
462
UH System Error, Refrigerant System Address Undefined
463
Check for Fan Motor Connector (Signal Line)
466
3.110 Check
466
Check for Fan Motor Connector (Power Supply Line)
467
Thermistor Resistance / Temperature Characteristics
468
Evaluation of Abnormal High Pressure
471
In Cooling Operation
471
In Heating Operation
472
Evaluation of Abnormal Low Pressure
473
Check for Power Transistor
475
Voltage Measuring Method
477
Pressure Sensor for Except RZQ(S)-B, RZQ-C7 and CMSQ
478
Pressure Sensor for RZQ(S)-B, RZQ-C7 and CMSQ
479
Electronic Expansion Valve Connector and Coil Resistance Criteria
480
Check for Factors Causing Wet Operation
481
Check for Excessive Refrigerant Charging
482
Check for Clogged Points
484
Check for Inadequate Refrigerant
485
Diagnosis of Inadequate Refrigerant
487
Fan Motor Pulse Check
489
Check for Causes of Rise in High Pressure
490
Check for Causes of Drop in Low Pressure
492
Method of Checking Inverter’s Power Transistors and Diode Modules
495
Electronic Circuit
496
Power Module Checking
497
Diode Module Checking
498
Broken Wire Check of the Connecting Wires
499
Warning
501
Advertisement
Daikin FMCQ100A7VEB Installation And Operation Manual (124 pages)
Air conditioning system
Brand:
Daikin
| Category:
Air Conditioner
| Size: 3.83 MB
Table of Contents
English
4
Air Conditioning System
1
Table of Contents
4
Before Installation
4
Important Information Regarding the Refrigerant Used
5
Selecting Installation Site
5
Preparations before Installation
6
Indoor Unit Installation
6
Refrigerant Piping Work
7
Drain Piping Work
8
Electric Wiring Work
9
Wiring Example
9
Field Setting
10
Wiring Example
10
Centralized Control
11
Test Operation
12
Maintenance
12
To Clean the Air Filter
12
To Clean the Suction Grille
12
Disposal Requirements
13
Wiring Diagram
14
Deutsch
15
Auswahl des Aufstellungsortes
16
Wichtige Informationen Hinsichtlich des Verwendeten Kältemittels
16
Installation der Inneneinheit
17
Vorbereitungen vor der Installation
17
Verlegen der Kältemittelleitungen
18
Verlegen der Elektroverkabelung
19
Verlegen der Kondensatleitungen
19
Bauseitige Einstellung
22
Installation der Zierblende
22
Verdrahtungsbeispiel
22
Probelauf
24
Wartung
24
Vorschriften zur Entsorgung
25
Schaltplan
26
Français
27
Choix du Lieu D'installation
28
Information Importante Relative Au Réfrigérant Utilisé
28
Installation de L'unité Intérieure
29
Préparations Avant L'installation
29
Intervention Sur Les Tuyaux de Réfrigérant
30
Tuyauterie de Vidange
31
Travaux de Câblage Électrique
32
Exemple de Câblage Et Comment Régler Le Dispositif de Régulation À Distance
33
Exemple de Câblage
34
Installation du Panneau Décoratif
34
Réglage Sur Place
34
Test de Fonctionnement
35
Exigences en Matière D'enlèvement
36
Maintenance
36
Schéma de Câblage
37
Español
49
Información Importante en Relación al Refrigerante Utilizado
50
Selección de la Ubicación de la Instalación
50
Instalación de Unidad para Interior
51
Preparaciones Antes de la Instalación
51
Instalación de Los Tubos de Refrigerante
52
Trabajo en la Tubería de Drenaje
53
Ejecución del Cableado Eléctrico
54
Ejemplo de Cableado y Cómo Ajustar el Mando a Distancia
55
Configuración de Obra
56
Ejemplo de Cableado
56
Instalación del Panel Decorativo
56
Prueba de Funcionamiento
58
Requisitos Relativos al Desecho de Residuos
59
Diagrama del Cableado
60
Italiano
61
Informazioni Importanti Sul Refrigerante Utilizzato
62
Scelta Della Posizione D'installazione
62
Installazione Dell'unità Interna
63
Preparazione Prima Dell'installazione
63
Installazione Delle Tubazioni del Refrigerante
64
Installazione Delle Linea DI Drenaggio
65
Esecuzione Dei Collegamenti Elettrici
66
Esempio DI Collegamento Elettrico E DI Impostazione del Telecomando
67
Esempio DI Collegamento
68
Impostazioni Sul Posto
68
Installazione del Panello Decorativo
68
Prova DI Funzionamento
69
Istruzioni Per lo Smaltimento
70
Manutenzione
70
Schema Elettrico
71
Unknown
72
Èïôá‹ Ùô˘ ¯Òúô˘ Âáî·ù¿Ûù·ûë
73
ËÌ·ÓÙÈΤ˜ ÏËÚÔÊÔڛ˜ Ô˘ ·ÊÔÚÔ‡Ó ÙÔ „˘Îùèîfi ˘Áúfi Ô˘ ¯ÚËÛÈÌÔÔÈ›ٷÈ
73
ÚÔÂÙÔÈ̷ۛ˜ ÚÈÓ ·Fi ÙËÓ ÂÁηٿÛÙ·ÛË
74
Áî·ù¿Ûù·ûë Ùë˜ Âûˆùâúè Ìôó
75
Úá·û›Â˜ Ûˆï‹Óˆûë˜ „˘Îùèîô
75
ˆÏëóòûâè˜ ·Ôûùú¿Ááèûë
76
Ïâîùúèî‹ Î·ïˆ‰›ˆÛë
78
Ú¿‰ÂÈÁÌ· ηψ‰›ˆÛ˘ Î·È Ú‡Iìèûë˜ ÙËϯÂÈÚÈÛÙ‹ÚÈÔ
78
Áî·ù¿Ûù·ûë Ùô˘ ‰È·îôûìëùèîô‡ ›Ó·î
79
Ú¿‰Âèáì· Î·ïˆ‰›ˆÛë
79
Ƒ‡Iìèûë ÛÙÔ ¯ÒÚÔ ÂÁηٿÛÙ·ÛË
80
Óù‹Úëûë
81
Ôîèì·ûùèî‹ Ïâèùô˘úá
81
ª¤ÙÚ· ·Fiúúè„Ë
82
È¿Áú·ìì· Î·ïˆ‰Èòûâˆó
83
Русский
95
Важная Информация Об Используемом Хладагенте
96
Выбор Места Установки
96
Монтаж Внутреннего Блока
97
Предварительные Операции Перед Монтажом
97
Рекомендации По Монтажу Труб Хладагента
98
Монтаж Электропроводки
100
Электрические Соединения И Задание Параметров На Пульте Управления
101
Монтаж Декоративной Панели
102
Примеры Электрических Соединений
102
Настройка На Месте
103
Пробный Запуск
104
Техническое Обслуживание
104
Утилизация
105
Электрическая Схема
106
Türkçe
107
Kullanılan Soğutucuya Ilişkin Önemli Bilgiler
108
Montaj Sahasının Seçilmesi
108
Montaj Öncesi Hazırlıklar
108
İç Ünite Montajı
109
Soğutucu Borularının Döşenmesi
110
Drenaj Borularının Döşenmesi
111
Elektrik Kablolarının Döşenmesi
112
Kablolama ÖrneğI Ve Uzaktan Kumandanın Yerleştirilmesi
112
Dekorasyon Panelinin Montajı
113
Kablo Bağlantı ÖrneğI
113
Saha Ayarı
113
BakıM
115
Test Işletimi
115
Bertaraf Gereksinimleri
116
Kablo Şeması
117
Daikin FMCQ100A7VEB Installation And Operation Manual (16 pages)
Air conditioning system
Brand:
Daikin
| Category:
Air Conditioner
| Size: 1.28 MB
Table of Contents
Table of Contents
4
Before Installation
4
Important Information Regarding the Refrigerant Used
5
Selecting Installation Site
5
Preparations before Installation
6
Indoor Unit Installation
6
Refrigerant Piping Work
7
Drain Piping Work
8
Electric Wiring Work
9
Wiring Example and How to Set the Remote Controller
9
Wiring Example
10
Installation of the Decoration Panel
10
Field Setting
10
Centralized Control
11
To Clean the Air Filter
12
To Clean the Suction Grille
12
Test Operation
12
Maintenance
12
Disposal Requirements
13
Wiring Diagram
14
Advertisement
Advertisement
Related Products
Daikin FMCQ100A8VEB
Daikin FMCQ50A7VEB
Daikin FMCQ60A7VEB
Daikin FMCQ125A7VEB
Daikin FMCQ71A7VEB
Daikin FMCQ60A8VEB
Daikin FMCQ50A8VEB
Daikin FMCQ71A8VEB
Daikin FMCQ125A8VEB
Daikin FMDQ60A7V3B
Daikin Categories
Air Conditioner
Heat Pump
Remote Control
Chiller
Fan
More Daikin Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL