5 - 38 WT4070/90 Wearable Terminal Integrator Guide
Selecting
Export All Profiles
with after a warm boot or cold boot.

Persistence

Export options and profiles to provide cold boot persistence for Windows CE 5.0 devices. Save the exported
registry files in the
option settings.
Currently, only server certificates can be saved for persistence. To save server certificates for persistence, save the
certificate files in the folder
NOTE User certificates cannot be saved for cold boot or clean boot persistence at this time.

Registry Settings

Use a registry key to modify some of the parameters. The registry path is:
HKLM\SOFTWARE\Symbol Technologies, Inc.\Configuration Editor
Registry Parameter Settings
Table 5-27
Key
CertificateDirectory
EncryptionMask
saves the current profile. This information is used to determine which profile to connect
folder to use them on a cold boot or clean boot and restore previous profile and
Application
to install the certificates automatically on a cold or clean boot.
Application
Type
Default
REG_SZ
\\Application
REG_DWORD
0x0000001F
Description
The default directory to find certificates.
Defines the supported encryption types. This is a
bitwise mask with each bit corresponding to an
encryption type.
1 = Type is supported
0 = Type is not supported
Bit Number
Encryption Type
0
None
1
40-Bit WEP
2
128-Bit WEP
3
TKIP
4
AES (Fusion 2.5 only)