3. INSTALLATION (CONTINUED)
PITCHED ROOF INSTALLATION
The top of the flue must be 60cm higher than the
highest point of the roof. Alternatively, there must be a
minimum distance of 5 meters from any higher section
of roof.
60cm
AURORA WOODFIRES INSTALLATION AND USER MANUAL
3.2 Positioning the external flue
!
1. Ensure the triple skin flue is installed as per Australian standards (see diagrams below).
60cm
+61 266 868408 PO 347 BOX BYRON BAY
5 m
1 meter
The minimum height of the flue
system further than 5 meters from
the highest point of the roof shall
be 1 meter above roof penetration.
NSW 2481