L42DF* Indoor Gas Fireplace

Section 3-3-1: Venting Layout: Wall mounted termination.

Selection of components and details of venting layout should adhere
to the following guidelines:
Vent terminations must not be recessed in walls or siding.
For Heat Shield requirements see Section 3-3-3.
Once the proposed venting layout has been determined refer
to Figure 14 or 16 to ensure the layout is acceptable.
Notes Wall Mounted Terminations: TOP VENT
All measurements for vertical or horizontal runs are measured
from center of the vent pipe.
Venting runs must fall within the limits set by the venting graph,
see Figure 14.
Wall mounted Terminations
The following details are some possible configurations for Wall mounted
terminations.
The Venting Graph: L42DF*
Measure the vertical height from the fireplace hearth to the centre of the
termination and the horizontal run from the fireplace flue collar to the wall
flange of the termination. Plot on the Venting Graph Figure 14 with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the
installation is acceptable.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 114" and the horizontal
run to the wall flange of the vent termination is 174", this would be
an acceptable installation.
Example B: (Acceptable Installation)
If the vertical dimension from the hearth is 60" and the horizontal
run to the wall flange of the vent termination is 42", this would be
an acceptable installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 60" and
the horizontal run to the wall flange of the vent termination is 144",
this would not be an acceptable installation.
Page 14
Installation
36
Figure 14. L42DF* Top Vent Venting Graph for wall mounted
terminations.
Flex or Rigid
section
Hearth
Figure 14a. Top Vented, wall mounted installation with one 90° bend.
The vent run must comply with Venting Graph for Top vent, wall mounted
terminations, Figure 14.
Figure 14b. Top Vented, wall mounted Multi-elbow installation. See
Venting Graph for Top vent, wall mounted terminations, Figure 14.
Acceptable vent run
within non-shaded area.
.
C
B
Unacceptable vent run
within shaded area.
40 1/2"
If your installation does not fall within
36"
the venting parameters, contact a
local Montigo dealer for Power
Venting options.
36" Max.
15'foot Max.
Solid Section
Flex Section
Hearth
A
0
Heat
Shield
Termination
40 1/2"
Min.
Exterior
Wall
Heat
Shield
Termination
Exterior
Wall
XG0181 - 150204