Setup For Operation; Arc Control - Thermal Arc 260S CC STICK Operating Instructions Manual

Inverter arc welder
Table of Contents

Advertisement

3.02 Setup for Operation

Arc Control

SETUP FOR OPERATION
The ARC CONTROL provides a suitable short circuit amperage to suit
individual welding situations when operating in the STICK welding
(SMAW) mode.
The Arc Control current is set to 45 Amperes (30%) in factory. If you want
to change Arc Control current, it will be necessary to change dip switch [9]
(DSW1) on the front panel PC Board (PCB7 [WK-4224 ] ).
The Dip Switch setting for the Arc Control current is classified as follows.
Dip Switch
1
2
3
ON
OFF OFF OFF
OFF
ON
OFF OFF
OFF OFF
ON
OFF OFF OFF
* Do not set other combinations.
24
F r o n t
Arc Control
4
Amperes Percentage
15A
30A
OFF
45A
ON
60A
Factory
Shipping
10%
-
20%
-
30%
40%
-
MANUAL 430429-447

Hide quick links:

Advertisement

Table of Contents
loading