Mastervolt MasterView Easy MkII User Manual

Mastervolt MasterView Easy MkII User Manual

Monitoring and control panel for the masterbus network

Advertisement

USERS MANUAL / GEBRUIKERSHANDLEIDING
BETRIEBSANLEITUNG / MANUEL D'UTILISATION
MANUAL DE UTILIZACION / INSTRUZIONI PER L'USO
MasterView Easy MkII
Monitoring and control panel for the MasterBus network
MASTERVOLT
Snijdersbergweg 93,
1105 AN Amsterdam
The Netherlands
Tel.: +31-20-3422100
Fax.: +31-20-6971006
www.mastervolt.com
ENGLISH:
NEDERLANDS:
DEUTSCH:
FRANÇAIS:
CASTELLANO:
ITALIANO:
v 1.5 September 2010
PAGE 1
PAGINA 25
SEITE 49
PAGINA 73
PÁGINA 97
PAGINA 121

Advertisement

Table of Contents
loading

Summary of Contents for Mastervolt MasterView Easy MkII

  • Page 1 USERS MANUAL / GEBRUIKERSHANDLEIDING BETRIEBSANLEITUNG / MANUEL D’UTILISATION MANUAL DE UTILIZACION / INSTRUZIONI PER L’USO MasterView Easy MkII Monitoring and control panel for the MasterBus network ENGLISH: PAGE 1 MASTERVOLT NEDERLANDS: PAGINA 25 Snijdersbergweg 93, DEUTSCH: SEITE 49 1105 AN Amsterdam FRANÇAIS:...
  • Page 2: Table Of Contents

    Add ............................ 15 6.6.7 Example ..........................15 6.6.8 Showing the Favourites page.................... 16 Configuring other devices......................... 16 Digital switches ..........................16 Digital switches ..........................16 Tanklevel Interface ........................... 17 ADDITIONAL INFORMATION........................18 September 2010 / MasterView Easy MkII / EN...
  • Page 3 CONTENTS MasterAdjust software ........................18 Ordering information ......................... 18 TROUBLE SHOOTING ..........................19 SPECIFICATIONS ............................21 Technical specifications........................21 Dimensions ............................22 EC DECLARATION OF CONFORMITY ....................... 23 EN / MasterView Easy MkII / September 2010...
  • Page 4: General Information

    GENERAL INFORMATION 1 GENERAL INFORMATION PRODUCT DESCRIPTION LIABILITY The Mastervolt MasterView Easy MkII is a panel to Mastervolt can accept no liability for: • monitor, configure and operate all connected consequential damage due to use of the devices in the MasterBus network.
  • Page 5: Safety

    Use of the MasterView Easy other than mentioned in point 2 is not considered to be consistent with the intended purpose. Mastervolt is not liable for any damage resulting from the above. EN / MasterView Easy MkII / September 2010...
  • Page 6: Masterbus

    MasterBus is For direct communication between the MasterBus used as power management system for all network and a product which is not from Mastervolt, connected devices, such as the inverter, battery the Modbus interface is recommended.
  • Page 7: How To Set Up A Masterbus Network

    As with all high speed data networks, MasterBus needs a terminating device on both ends of the network . Do not make T-connections in the network. Terminating Terminating device device Figure 6 Figure 3 EN / MasterView Easy MkII / September 2010...
  • Page 8: Installation

    (1). • Insert the MasterBus connection cables into the MasterBus data ports and click the panel into the outer housing (2). • Reattach the front (3), see figure 8. Figure 8 September 2010 / MasterView Easy MkII / EN...
  • Page 9: Operation

    (see figure 11). You will then return to the main for any particular device connected, menu. except for the MasterView Easy itself. Refer to the user’s manual of the connected device for an overview of all available readouts and settings. EN / MasterView Easy MkII / September 2010...
  • Page 10: Control

    Go to Go to Mastership Configuration Alarm Go to Product Alarms ASTERVOLT ASTERVOLT Unlock Press shortly: 0-2 sec. Press long: longer than 2 sec. Figure 10: Operation of the MasterView Easy, opening screens September 2010 / MasterView Easy MkII / EN...
  • Page 11: Maintenance

    If you need to clean the touch screen without Press button long again to unlock keyboard. controlling function, use Keyboard Lock. Press button long to lock keyboard, see figure 10. EN / MasterView Easy MkII / September 2010...
  • Page 12: Monitoring And Configuration

    Backlight Illumination of the display’s backlight. Auto Auto/On/Off Switch X Configurable switch on the MasterView Easy X = 1 to 6 Go to configuration Press Enter to continue with the configuration menu. September 2010 / MasterView Easy MkII / EN...
  • Page 13: Masterview Easy Configuration

    In Connected favour., a list of the added monitoring items for the chosen areas is shown. This list is read only in user level. pressed. The characters change then in second 6.2.1 Changing of characters Changing of characters, for instance the yacht gear. name, is accelerated by keeping the up/down arrow EN / MasterView Easy MkII / September 2010...
  • Page 14: Masterview Easy Events

    It is used in combination with a pulse switch. FOLLOW THE TOGGLE LEADER If two or more targets of the MasterView Easy MkII are configured for one toggle switch, the first event for this switch is the leading toggle event. The other events are the following toggle events.
  • Page 15: Name Favourites Page

    General. Choose the group, starting to count at 1. Under Connect to select Area 1. Under Device select your MasterShunt. Select Group no. 1 and Item no. 1. Finally press Add and confirm. Figure 13: Configuration of Area 1 EN / MasterView Easy MkII / September 2010...
  • Page 16: Showing The Favourites Page

    6.2 for the Configuration Lock of all connected figure 13. devices. NOTE: To have a switch displayed at the Favourites page, you need to add it! Refer to section 6.6.7 for an example. September 2010 / MasterView Easy MkII / EN...
  • Page 17: Tanklevel Interface

    NOTE: Only the MasterView Easy MkII switches can be configured for the Easy MkII feedback function! Figure 16: Configuration, monitoring of switch 1-6 Figure 17: Switch configuration at the MasterView Easy MkII Figure 18: Feedback configuration at the Digital DC 10x10A Favourites 0% 100% Kitchen Figure 19: Favourites page with switch.
  • Page 18: Additional Information

    * These parts are standard included with the delivery of the MasterView Easy Mastervolt can offer a wide range of products for your electrical installation, including an extended program of components for your MasterBus network. Our website www.mastervolt.com shows an overview of all our products and free downloadable software.
  • Page 19: Trouble Shooting

    1 day. The device name is Device name has not yet been set. Adjust device name, see section 6.2. not correct. EN / MasterView Easy MkII / September 2010...
  • Page 20 Click the X repeatedly to enter the device list. This slightest idea where in unexpected screens. is the MasterView Easy starting screen. It the menu structure you changes to your Favourites page automatically. have ended up. September 2010 / MasterView Easy MkII / EN...
  • Page 21: Specifications

    MasterVision compatible: Power consumption: Off: 16 mW On: 160 mW (backlight off); 900mW (backlight on) Dimensions: See section 9.2 Required depth: 38 mm minimum Weight: 230 g (0.50 lb) Protection degree: IP 21 EN / MasterView Easy MkII / September 2010...
  • Page 22: Dimensions

    SPECIFICATIONS DIMENSIONS Fig. 22: Dimensions in mm (inch) of the panel without and with outer casing. September 2010 / MasterView Easy MkII / EN...
  • Page 23: Ec Declaration Of Conformity

    Is in conformity with the provision of the EC EMC directive 89/336/EEC and amendments 92/31/EEC, 93/68/EEC. Low voltage directive: 2006/95/EC The following harmonised standards have been applied: Generic emission standard: EN 50081-1:1992 Generic immunity standard: EN 50082-1:1997 Amsterdam, P. F. Kenninck, C.E.O. MASTERVOLT EN / MasterView Easy MkII / September 2010...
  • Page 24 Snijdersbergweg 93, 1105 AN Amsterdam, The Netherlands Tel : + 31-20-3422100 Fax : + 31-20-6971006 Email : info@mastervolt.com...

Table of Contents