Mastervolt MasterVision User Manual

Mastervolt MasterVision User Manual

Mass charger alarm interface, gmdss - global maritime distress & safety system

Advertisement

Quick Links

USERS MANUAL
Mass Charger Alarm
Interface
GMDSS - Global Maritime Distress & Safety System
MASTERVOLT
Snijdersbergweg 93,
1105 AN Amsterdam
The Netherlands
Tel.: +31-20-3422100
ENGLISH:
PAGE 1
Fax.: +31-20-6971006
www.mastervolt.com
Copyright © 2013 Mastervolt, v 2.1 January 2013

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MasterVision and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mastervolt MasterVision

  • Page 1 USERS MANUAL Mass Charger Alarm Interface GMDSS - Global Maritime Distress & Safety System MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 ENGLISH: PAGE 1 Fax.: +31-20-6971006 www.mastervolt.com Copyright © 2013 Mastervolt, v 2.1 January 2013...
  • Page 2: Table Of Contents

    Wiring details GMDSS interface ........................16     Technical specifications ........................... 17     Ordering Information ............................17     EC DECLARATION OF CONFORMITY ........................18 Copyright © 2013 Mastervolt / January 2013 / GMDSS Mass Charger Alarm Interface Copyright / EN...
  • Page 3: General Information

    Never remove the identification label. CHANGES TO THE GMDSS INTERFACE Changes to the GMDSS Interface may be carried out only after obtaining the written permission of Mastervolt. EN / GMDSS Mass Charger Alarm Interface / January 2013 / Copyright © 2013 Mastervolt...
  • Page 4: Safety Guidelines And Measures

    • To open the cabinet of the Mass Battery Charger, follow the instructions as stated in the user’s manual of the battery charger. Copyright © 2013 Mastervolt / January 2013 / GMDSS Mass Charger Alarm Interface Copyright / EN...
  • Page 5: Warning Regarding Life Support Applications

    Mastervolt responsible for any claims arising from the use of the GMDSS Interface parts in the life support equipment. EN / GMDSS Mass Charger Alarm Interface / January 2013 / Copyright © 2013 Mastervolt...
  • Page 6: Operation

    Three potential-free switch over contacts for DC voltage alarm, Charger alarm and AC mains alarm; • Test mode function; • Shunt included in the delivery • Wide DC-voltage operating range Copyright © 2013 Mastervolt / January 2013 / GMDSS Mass Charger Alarm Interface Copyright / EN...
  • Page 7: Main Menu

    If set to ON, screens marked with ** will not be shown. Shows the actual charge current 024.0A Factory setting: OFF (Amps). Adjustable range: ON/OFF EN / GMDSS Mass Charger Alarm Interface / January 2013 / Copyright © 2013 Mastervolt...
  • Page 8 "Charger in battery voltage force float” Refer to the User’s manual of the battery Adjustable range:8.0…18.0V/18.0…36.0V charger for details. Factory setting: OFF Adjustable range: ON/OFF Copyright © 2013 Mastervolt / January 2013 / GMDSS Mass Charger Alarm Interface Copyright / EN...
  • Page 9: Alarms

    Check at least once a year if all cable and wire connections are still firmly connected. PROBLEM SOLVING Refer to section 5 if a problem occurs EN / GMDSS Mass Charger Alarm Interface / January 2013 / Copyright © 2013 Mastervolt...
  • Page 10: Installation And Commissioning

    2 mm and 5 mm flat blade screwdrivers. A complete set of spanners, pliers and wrenches may be helpful during the installation of the GMDSS Interface Copyright © 2013 Mastervolt / January 2013 / GMDSS Mass Charger Alarm Interface Copyright / EN...
  • Page 11: Connection

    Run the 6 pole modular communication cable Refer to section 6.1. between the battery charger and the GMDSS Interface. EN / GMDSS Mass Charger Alarm Interface / January 2013 / Copyright © 2013 Mastervolt...
  • Page 12: Installation Drawing

    This schematic is to illustrate the general placement of the GMDSS Interface in a circuit. It is not meant to provide detailed wiring instructions for any particular electrical installation. Figure 4: Installation drawing of the GMDSS Interface Copyright © 2013 Mastervolt / January 2013 / GMDSS Mass Charger Alarm Interface Copyright / EN...
  • Page 13: Settings On The Battery Charger

    Figure 6: Location of the DIP-switches at battery charger models Mass 12/60-2, Mass 12/80-2 and Mass 24/50-2 Figure 7: Location of the DIP-switches at battery charger models Mass 24/75 and Mass 24/100 EN / GMDSS Mass Charger Alarm Interface / January 2013 / Copyright © 2013 Mastervolt...
  • Page 14: Commissioning

    (chapter 4). function F17 of the Install menu (refer to section 3.3.2) Now the GMDSS Interface is ready for operation. Copyright © 2013 Mastervolt / January 2013 / GMDSS Mass Charger Alarm Interface Copyright / EN...
  • Page 15: Trouble Shooting

    5 TROUBLE SHOOTING If you cannot solve a problem with the aid of this table, contact your local Mastervolt Service Centre. See www.mastervolt.com. Make sure you have the Article and serial number (see section 1.6) as well as the Software version (see section 3.3.2) of the GMDSS-Interface present if you have to contact your local Mastervolt Service Centre to solve a problem.
  • Page 16: Technical Data

    Mass Charger QRS 232 QRS. 232 communication to Mass Charger, 6 pole, RJ12, cross wired See section 3.4 for an overview of conditions for the alarm functions Copyright © 2013 Mastervolt / January 2013 / GMDSS Mass Charger Alarm Interface Copyright / EN...
  • Page 17: Technical Specifications

    * These parts are standard included with the delivery of the GMDSS Interface Mastervolt can offer a wide range of products for your electrical installation, including AGM batteries, GEL batteries, DC distribution kits, battery switches, battery cables, battery terminals and Mastervision switchboards See our website www.mastervolt.com for an extensive overview of all our products...
  • Page 18: Ec Declaration Of Conformity

    2006/95/EC (Safety directive); the following harmonized standard has been applied: EN 60950-1:2001+ A11:2004 (Low voltage standard) Amsterdam, H.A. Poppelier Product Manager Marine & Mobile Mastervolt Copyright © 2013 Mastervolt / January 2013 / GMDSS Mass Charger Alarm Interface Copyright / EN...
  • Page 19 NOTES NOTES EN / GMDSS Mass Charger Alarm Interface / January 2013 / Copyright © 2013 Mastervolt...
  • Page 20 Snijdersbergweg 93, 1105 AN Amsterdam, The Netherlands Tel : + 31-20-3422100 Fax : + 31-20-6971006 Email : info@mastervolt.com...

This manual is also suitable for:

70400050217091502170920021709300

Table of Contents