Converting the gas regulator on the valve
1). On the right side (control side) of the unit, remove 2 screws
that enable the valve to swing away from the unit.
Figure 2 Sec.6
2). Swing the valve away from the unit in order to get access to
the front of the valve and regulator. Be careful not to damage gas
lines or wires.
Figure 3 Sec.6
XG0523-150909
Installation
3). Using a T20 Torx screw driver, remove the 2 screws that attach
the stepper motor to the valve.
Figure 4 Sec.6
4). Remove the screws, stepper motor and rubber diaphragm.
Figure 5 Sec.6
5). Remove the top 2 screws that hold the control mounting
bracket in place.
Figure 6 Sec.6