Maintenance And Service; Proper Shutdown Procedure; Quick Reference Maintenance Chart - Quadra-Fire MTVI-E2-MBK Owner's Manual

Mt. vernon e2 insert pellet stove
Hide thumbs Also See for MTVI-E2-MBK:
Table of Contents

Advertisement

3

Maintenance and Service

When properly maintained, your fi replace will give you
many years of trouble-free service. Contact your dealer
to answer questions regarding proper operation, trou-
bleshooting and service for your appliance. Visit www.
quadrafi re.com to locate a dealer. We recommend annual
service by a qualifi ed dealer.
A. Proper Shutdown Procedure
Turn dial control to OFF, let appliance completely cool and
exhaust blower must be off. Now you can unplug appli-
ance before servicing.
This pellet insert has a manufacturer-set minimum low burn
rate that must not be altered. It is against federal regulations
to alter this setting or otherwise operate this pellet insert in a
manner inconsistent with operating instructions in this manual.
B. Quick Reference Maintenance Chart
Cleaning or Inspection
Firepot
Ash Removal from Firebox
Glass
Hopper
Exhaust Path, Drop Tube and Behind
Baffl es
Door Handle & Gasket Inspection
Blower, Convection
Blower, Exhaust
Firebox - Prepare for Non-Burn Season
Venting System
NOTICE: These are recommendations. When burning high ash content pellet fuel or a corn/pellet
mix you may need to clean the fi repot several times a day. Clean the stove and fi repot
more frequently if you encounter heavy build-up of ash at the recommended interval or you
see soot coming from the vent. Not properly cleaning your appliance on a regular basis
will void your warranty.
July 1, 2015
Follow the detailed instructions found in this
section for each step listed as referenced in
the chart below.
Frequency
As needed
About 5 bags of fuel depend-
ing on ash build-up
When clear view of fi repot
becomes obscure
Every ton of fuel (50 bags)
Every ton of fuel (50 bags) or
more frequently
Prior to heating season
Every ton of fuel or more fre-
quently depending on perfor-
mance
Every ton of fuel or more fre-
quently depending on perfor-
mance
At end of heating season
Every 3 tons of fuel or more
frequently depending on per-
formance
7082-132H
MT. VERNON E2 INSERT
CAUTION
Shock and Smoke Hazard
• Smoke spillage into room can occur if appliance
is not cool before unplugging.
• Risk of shock if appliance not unplugged before
servicing appliance.
Daily Weekly Monthly
OR
X
OR
X
OR
X
OR
OR
OR
OR
OR
OR
OR
Yearly
X
X
X
X
X
X
X
15