6.5 Panel FAQ005_HDL BUSpro
Q:
Whenever I long press a button and try to dim up, I always want to dim to at least 50%, so
any level lower than 50% is not practical at all for me, can I bypass the lower segment and
dim upward from 50%, this saves me just a little pressing time, but still, is it possible?
A:
Yes, there is minimum dimming setting in the Panel, please check the screen shot below.
6.6 Panel FAQ006_HDL BUSpro
Q:
I can preset whether to save my customized level or not so that next time I turn it on it can
recall my customized level or simply go to 100%, but If I choose the
former option and the load happens to be, e.g.,
fluorescent light, if you dim it too low and save, next time it is hard for you to turn it on, it is
due to the characteristic of the gas-discharging light, not the problem
of the Dimmer, but in this case I need to limit the dimming range somehow. Even if I have
a good load that can be dimmed from 0% to 100%, if the kids dim it to 1%, then
still it is hard to notice it is on, you press it again and again, it just toggles between 0% ad
1%, both are not so much noticeable. In both cases, chances are the end-user
will call me at midnight, how can I prevent this?
A:
There is such setting in the Panel, please refer to FAQ5.