GRASS VALLEY 8943FC Instruction Manual
GRASS VALLEY 8943FC Instruction Manual

GRASS VALLEY 8943FC Instruction Manual

4 ch fiber to electrical converter

Advertisement

Quick Links

8943FC
4 CH FIBER TO ELECTRICAL CONVERTER
Instruction Manual
Software Version 1.0.2
071877100
MAY 2011

Advertisement

Table of Contents
loading

Summary of Contents for GRASS VALLEY 8943FC

  • Page 1 8943FC 4 CH FIBER TO ELECTRICAL CONVERTER Instruction Manual Software Version 1.0.2 071877100 MAY 2011...
  • Page 2 CERTIFICATE Certificate Number: 510040.001 The Quality System of: Grass Valley USA, LLC and its Grass Valley Affiliates Headquarters: 400 Providence Mine Road 15655 SW Greystone Ct. Brunnenweg 9 Nevada City, CA 95945 Beaverton, OR 97006 D-64331 Weiterstadt United States United States...
  • Page 3 8943FC 4 CH FIBER TO ELECTRICAL CONVERTER Instruction Manual Software Version 1.0.2 071877100 MAY 2011...
  • Page 4 Benelux/Belgium: +32 (0) 2 334 90 30 Benelux/Netherlands: +31 (0) 35 62 38 42 1 N. Europe: +45 45 96 88 70 Germany, Austria, Eastern Europe: +49 6150 104 444 UK, Ireland, Israel: +44 118 923 0499 Copyright © Grass Valley USA, LLC. All rights reserved. This product may be covered by one or more U.S. and foreign patents.
  • Page 5: Table Of Contents

    About This Manual ........... . . 8943FC 4 Channel Fiber to Electrical Converter Module .
  • Page 6 ..............8943FC — Instruction Manual...
  • Page 7: Preface

    Safety and Regulatory Compliance described in the GeckoFlex 8900 Series frame documentation (see the GeckoFlex Frames 8900FX/FF/FFN Signal Processing System Instruction Manual). All Modular product manuals can be found on-line in PDF format at this link: www.grassvalley.com/docs/modular 8943FC — Instruction Manual...
  • Page 8 Preface 8943FC — Instruction Manual...
  • Page 9: 8943Fc 4 Channel Fiber To Electrical Converter Module

    Model options are given in Table 1 on page • Up to ten 8943FC modules in the same 2 RU GeckoFlex frame. • Two electrical BNC outputs for each of the four fiber optic input chan- nels.
  • Page 10 Introduction The 8943FC can be populated with the dual receiver SFP devices listed in Table 1. SFP devices come in kits containing the SFP device, a mounting bracket, and a fiber cable assembly. Kit part numbers are indicated by a -K at the end of the part number.
  • Page 11: Installation

    Installation Installation The 8943FC model consists of a front and rear module set that can only be installed in a GeckoFlex frame. Two fiber optic dual transmitter SFP device kits, shipped separately, must also be installed for full functionality of the module.
  • Page 12: Module Installation Precautions

    Table 6 on Mechanical page • If using a fiber optic SFP device on the fiber-ready front module, handle it carefully, use anti-static precautions, and read the Installation on page 11 before cabling. 8943FC — Instruction Manual...
  • Page 13: Rear Module Installation

    Note All unused rear slots in a GeckoFlex frame should have a blank rear adapter cover installed. Figure 2. Installing Rear Module Use retainer clip or needlenose pliers to pull out blank after removing retainer clips 8943FC — Instruction Manual...
  • Page 14: Sfp Device Installation

    SFP Device Installation Two optional dual channel CWDM receiver SFP devices can be installed on an 8943FC module. Both are installed on the front of the module circuit board. The type of SFP device depends on the application of the module and the 8939FCA or 8939FCB module it will be feeding.
  • Page 15 Installation of each SFP device involves three steps: 1. Mount the metal bracket to the SFP device, 2. Mount the SFP device and bracket on the top side of the 8943FC front module, and 3. Install the fiber cable assembly to the SFP device and the rear LC adapters.
  • Page 16 Figure 7 shows an example of a finished SFP installation on a 8943FC module with the locations of the hardware components, connectors, and plastic cable guides.
  • Page 17 SFP device and connector J6 as described in Installation on page 2. Align the SFP device with the right angle bottom SCA-2 connector (J6) and the mounting screws on the 8943FC module (Figure 3. Loosen the two screws slightly (do not remove them completely) with a torx screwdriver so the mounting bracket straps can slide under the screws.
  • Page 18 Fiber 1 (B) is the bottom cable from the SFP device and Fiber 2 (A) is the top cable. Note the silkscreened F1 (B) and F2 (A) as shown in the detail in Figure Figure 10. F1 and F2 Fiber Cable Silkscreen Guide Detail 8943FC — Instruction Manual...
  • Page 19 SFP device by holding the strain relief boot directly behind the connector housing as shown in Figure 12 on page 20. Push on the strain relief until you hear a click, indicating the connectors are properly mated. 8943FC — Instruction Manual...
  • Page 20 5. Put the fiber cable assembly through the cable guide on the back of the circuit board to hold it in place (Figure 13). Note the silkscreened F3 (B) and F4 (A) guides as shown in the detail in Figure Figure 13. F3 and F4 Fiber Cable Silkscreen Guide Detail 8943FC — Instruction Manual...
  • Page 21 • Fiber In 4 = 1550nm If you are using 8943FCs to multiplex 8 or 16 frequencies through the 8939FCA/FCB modules, the other 8943FCs should be equipped with the SFP devices as described in CWDM 16 Channel Configuration on page 8943FC — Instruction Manual...
  • Page 22: Front Module Installation

    8. Replace the front cover for configuring the module using remote controls. Figure 16. Front Module Installation Front Module Side View Locking Pin Module installed Slide top and bottom card carriers on module over top and bottom guides on right of slot. 8943FC — Instruction Manual...
  • Page 23: Cabling

    Installation Cabling Cabling is done on the rear BNCs of the 8943FC-R module illustrated in Figure Note Before making any fiber connections, refer to the Fiber Optic Cleaning Requirement on page Figure 17. 8943FC-R Rear Module 8943FC-R CH 1B Electrical Out...
  • Page 24: Fiber Optic Inputs

    Before making any fiber connections, follow the required fiber optic cleaning recommendations given in Installation on page For the fiber input ports, the 8943FC-R rear module shall follow the channel allocation convention shown in Figure 18. Optical channel 1 and channel 3...
  • Page 25: Cwdm Configuration

    1310nm SFP Fiber Out Fiber In When an 8943FC module is populated with CWDM SFP devices, a stan- dard crossing duplex cable is required when connecting the 8943FC modules to the 8939FCA modules. Crossing is in reference to the logical A/B nomenclature associated with...
  • Page 26 • Two 8943CF 4 Channel Electrical to Fiber Converter modules with one of each type of CWDM SFP device • Two 8943FC 4 Channel Fiber to Electrical Converter modules with one of each type of CWDM SFP device • Two fiber-ready Grass Valley GeckoFlex modules with 1310nm SFP...
  • Page 27 Installation Figure 22. CWDM Configuration Channels 1-8 8943FC — Instruction Manual...
  • Page 28 Installation CWDM 16 Channel Configuration The 8943FC can also be used with the 8939FCA and 8939FCB to provide 16 channels of video over a single fiber connection. As shown in the simple block diagram in Figure 23, the two 8939FCB...
  • Page 29 • SFP-CWDM3G-3-K Dual Transmitter (1550nm/1570nm frequencies) • SFP-CWDM3G-4-K Dual Transmitter (1590nm/1610nm frequencies) The 8943FC modules receiving the fiber signals from the 8939FCA should have SFP-13103G-M1DRX-K Dual Receivers installed in each of the four locations. Refer to the detailed diagram in...
  • Page 30 Installation Figure 24. 8939FCB Configuration – Channels 9 -16 8943FC — Instruction Manual...
  • Page 31: Configuration And Monitoring

    Configuration and Monitoring Configuration and Monitoring 8943FC module configuration and monitoring can be performed locally using the onboard controls or using a web browser GUI interface when the 8900NET Network Interface module is present in the GeckoFlex frame. Control and monitoring is described in the following sections: •...
  • Page 32: Auto Reclock/Mute Mode

    If no input signal or a signal other than 1485Mb/s is detected by the module, the output of the reclocker will be muted and the outputs will be static (muted). With input reporting enabled, the signal input will be reported as Not Present. 8943FC — Instruction Manual...
  • Page 33: Sd 270M Mode

    If a bit rate other than 270Mb/s is detected by the module or no input signal is detected, reclocking will not be performed and the signal will be auto- matically bypassed to the outputs. With input reporting enabled, the input signal will be reported as Not Monitored. 8943FC — Instruction Manual...
  • Page 34: Local Monitoring And Configuration

    Configuration and Monitoring Local Monitoring and Configuration The 8943FC module can be configured and monitored locally using on- board rotary and paddle switches and the status and configuration LEDs mounted on the top of the module circuit board. If an 8900NET (Net Card)
  • Page 35 LEDs and the Present Not Present conditions of the output based on the operating mode, the input presence, the actual input standard, and the Input Reporting State. 8943FC — Instruction Manual...
  • Page 36 Not Present Disabled Not Monitored Reclocked Fixed 2970M/Mute Present 2970Mb/s Green Blue 2970Mb/s Enabled Present When an input is missing on any input, the red FAULT LED will flash on the front of the module circuit board. 8943FC — Instruction Manual...
  • Page 37: Local Mode Configuration

    It can be changed to lock out remote control if desired (LOC posi- tion, pins 1-2). Figure 26. On-board Configuration Switches and LEDs CONF LED Input Op Mode Configuration LEDs Rotary Switch, S1 Paddle Switch, S2 Local/Remote Jumper 8943FC — Instruction Manual...
  • Page 38 Recall factory defaults (all channels have Reporting Enabled and Recall Auto/Mute mode selected). Note When configuration is complete, the Function switch should be parked in an unused position such as 0 during normal operation to avoid changing the mode accidently with the paddle switch. 8943FC — Instruction Manual...
  • Page 39: Remote Monitoring And Controls

    Configuration and Monitoring Remote Monitoring and Controls The 8943FC module can be configured and monitored remotely when an 8900NET module is installed in the GeckoFlex frame using the web-based GUI or the Newton Control Panel. 8900NET Module Information Refer to the 8900NET Network Interface Module Instruction Manual for infor- mation on the 8900NET Network Interface module and setting up and operating the GeckoFlex frame network.
  • Page 40: Web Browser Interface

    Figure 28 on page 41. The modules can be addressed by clicking either on a specific module icon in the frame status display or on a module name or slot number in the link list on the left. 8943FC — Instruction Manual...
  • Page 41 Content display section displays the information page for the selected frame or module (frame slot icons are also active links). Refresh button for manual update of page 8943FC — Instruction Manual...
  • Page 42: Web Page Links

    (page 48), • Slot Config – provides Locate Module and Slot Memory functions along with links to the 8900NET SNMP, LED Reporting, and Frame Alarm configuration web pages (page Figure 29. 8943FC Web Page Links 8943FC — Instruction Manual...
  • Page 43: Status Web Page

    8900NET module. • Rear Module – indicates status of the 8943FC-R module. • Front Processing Module – indicates status of the 8943FC front module. • Fiber Module 1 – indicates the status of the optional fiber optic SFP device installed in connector J6 on the top side of the module.
  • Page 44 Configuration and Monitoring The Status web page shown in Figure 30 show all inputs present and locked and no errors of any type. Figure 30. 8943FC Status Web Page – No Error Messages 8943FC — Instruction Manual...
  • Page 45 Configuration and Monitoring Figure 31 illustrates the Status web page reporting that the top SFP device is not installed. Figure 31. 8943FC Status Web Page – No SFP Installed 8943FC — Instruction Manual...
  • Page 46 Not Monitored Not Monitored Present Present Present Present Present Present Not Monitored Present Present Present Not Monitored Present Present Present Not Monitored Present Present Present Not Monitored Present Present Present Present Present Present Present Present Present 8943FC — Instruction Manual...
  • Page 47: I/O Config Web Page

    32) for the 8943FC-R rear module for rear module configuration and signal status reporting. this All of the input and output connectors on the corresponding 8943FC-R rear link module are illustrated on the I/O Config web page. The inputs can be con- figured with the following controls: •...
  • Page 48: Settings Web Page

    • 3G 2970M mode • HD 1485M mode • SD 270M mode • Manual Bypass HD/3G • Manual Bypass SD Each of the operating modes are described in detail in Input Operating Modes Overview on page 8943FC — Instruction Manual...
  • Page 49 Configuration and Monitoring Figure 33. Settings Web Page – All Signals Present 8943FC — Instruction Manual...
  • Page 50: Slot Config Web Page

    • Locate Module this • Slot Identification link • Slot Memory • Frame Health Reporting • LED Reports • SNMP Trap Reports Each of these functions is described in detail below. Figure 34. Slot Config Web Page 8943FC — Instruction Manual...
  • Page 51 Learn Module Config current configuration for this slot. The configuration is saved on the 8900NET module. If the 8900NET module is removed or powered down, the stored configurations are not saved. 8943FC — Instruction Manual...
  • Page 52: Software Updating

    Refer to the 8900NET Instruction Manual for complete details on using the 8900NET web pages. Software Updating Software updating of the 8943FC modules is done using the NetConfig Networking Application PC option. This application is available free of charge from the Grass Valley web site.
  • Page 53: Specifications

    Specifications Specifications Table 6 gives the overall specifications for the 8943FC module. Refer to Table 7 on page 54 for Dual Receiver/Transceiver SFP detailed specifica- tions. Table 6. 8943FC Specifications Parameter Value Serial Digital Coax Output Connector 2 BNCs per input channel (total of 8)
  • Page 54 Specifications Table 6. 8943FC Specifications Parameter Value Environmental Frame temperature range Refer to GeckoFlex Frames 8900FX/FF/FFN Signal Processing Systems Instruction Manual Operating humidity range www.grassvalley.com/docs/modular Non-operating temperature Power Power consumption 7.5 Watts with two SFP devices Table 7. Optional Receiver/Transceiver Fiber Optic SFP Device Specifications...
  • Page 55: Status Monitoring

    • LEDs on the Frame, 8900NET module, and individual frame media modules, • Web browser status reporting for each frame component, and • SNMP traps, captured by Grass Valley’s NetCentral or another SNMP Manager Application. Note SNMP trap information is only available when an SNMP Agent has been installed and configured.
  • Page 56: Led Reporting

    When SNMP Agent software is installed on the 8900NET module, enabled status reports are sent to an SNMP Manager such as the Grass Valley’s NetCentral application. DIP switch. Connection and use of the Frame Alarm is covered in detail in the 8900NET Network Interface Instruction Manual.
  • Page 57: Service

    If power has been cut off to module, remove the module and replace it in the frame to reset. If the problem persists contact Grass Valley Customer Service.
  • Page 58: Functional Description

    Functional Description Functional Description An overall block diagram for the 8943FC module is shown in Figure Figure 35. 8943FC Block Diagram Bypass Cable Driver #1 Ch 1 Dual RX SFP Reclock Equalizer #1 A and B Out RX #1 Bypass...
  • Page 59: Configuration Summary Table

    Configuration Summary Table Table 8 provides a complete summary of the 8943FC module functions and a comparison of the functionality available with each control type along with the ranges and default values for each parameter and notes on each control.
  • Page 60 Configuration Summary Table 8943FC — Instruction Manual...
  • Page 61: Index

    CONFIG LED during configuration summary table configuration summary table HD 1485M mode using local controls using remote GUI control panel I/O Config web page CWDM (Coarse Wavelength Division Multiplexing) input/output status summary configuration installation 8943FC-R rear module 8943FC — Instruction Manual...
  • Page 62 Settings web page HD/3G mode SFP devices SD mode fiber device missing Module Health Bus installation module installation precautions types used on 8943FC module repair Signal names Module Status web page I/O web page Slot Config web page slot memory SNMP reporting...
  • Page 63 Index warning messages on Status web page web browser interface links overview recommended web site documentation FAQ database Grass Valley software download 8943FC — Instruction Manual...
  • Page 64 Index 8943FC — Instruction Manual...

Table of Contents