GRASS VALLEY 8935CF Instruction Manual
GRASS VALLEY 8935CF Instruction Manual

GRASS VALLEY 8935CF Instruction Manual

4 ch electrical to fiber converter
Hide thumbs Also See for 8935CF:

Advertisement

Quick Links

8935CF
4 CH ELECTRICAL TO FIBER CONVERTER
Instruction Manual
SOFTWARE VERSION 1.0.0
071854300
MAY 2007

Advertisement

Table of Contents
loading

Summary of Contents for GRASS VALLEY 8935CF

  • Page 1 8935CF 4 CH ELECTRICAL TO FIBER CONVERTER Instruction Manual SOFTWARE VERSION 1.0.0 071854300 MAY 2007...
  • Page 2 Affiliate with the N.V. KEMA in The Netherlands CERTIFICATE Certificate Number: 510040.001 The Quality System of: Grass Valley, Inc. 400 Providence Mine Road 15655 SW Greystone Ct. 10 Presidential Way Nevada City, CA 95945 Beaverton, OR 97006 Floor, Suite 300...
  • Page 3 8935CF 4 CH ELECTRICAL TO FIBER CONVERTER Instruction Manual SOFTWARE VERSION 1.0.0 071854300 MAY 2007...
  • Page 4 Benelux/Belgium: +32 (0) 2 334 90 30 Benelux/Netherlands: +31 (0) 35 62 38 42 1 N. Europe: +45 45 96 88 70 Germany, Austria, Eastern Europe: +49 6150 104 444 UK, Ireland, Israel: +44 118 923 0499 Copyright © Grass Valley. All rights reserved. This product may be covered by one or more U.S. and foreign patents.
  • Page 5: Table Of Contents

    About This Manual ........... . . 8935CF 4 Channel Electrical to Fiber Converter Module .
  • Page 6 ..............8935CF — Instruction Manual...
  • Page 7: Preface

    Preface About This Manual This manual describes the features of the 8935CF module and the corre- sponding rear modules in the GeckoFlex frame. As part of this family of modular products, it is subject to the Safety and Regulatory Compliance information described in the GeckoFlex Frames Instruction Manual.
  • Page 8 Preface 8935CF — Instruction Manual...
  • Page 9: 8935Cf 4 Channel Electrical To Fiber Converter Module

    SFP dual transmitter fiber optic submodules mounted on the front module. • Up to ten 8935CF modules in the same 2 RU GeckoFlex frame. • Four electrical BNC inputs to up to four fiber optic outputs and an iden- tical electrical BNC output for each channel.
  • Page 10: Fiber Optic Cleaning Requirement

    Introduction The 8935CF can be populated with any two of the following SMV_SFP (Strap Mount Video Small Form-factor Pluggable) dual transmitter sub- modules, depending on the application desired: • SFP-1310-STRX – Dual Transmitter with 1310nm FP lasers • SFP-CWDM-1 – Dual Transmitter with CWDM lasers (1440/1490nm) •...
  • Page 11: Installation

    Installation Installation The 8935CF model consists of a front and rear module set that can only be installed in a GeckoFlex frame. Two SFP fiber optic dual transmitter sub- modules, shipped separately, must also be installed for full functionality of the module.
  • Page 12: Rear Module Installation

    To remove a rear module already installed, follow the same steps. It is helpful to first remove the front module so the rear can be pulled out more easily. 3. Before installing the 8935CF rear module, check that the blue plastic fiber optic connectors on the rear module are not mounted too rigidly.
  • Page 13: Smv_Sfp Submodule Installation

    SMV_SFP Submodule Installation Two dual channel Tx-Tx SMV_SFP submodules must be installed on an 8935CF module to provide full functionality. The type of submodule depends on the application of the module. The submodules must be one of the following models from Grass Valley: •...
  • Page 14 • SFP-CWDM-1 – 1440nm (44) and 1490nm (49) • SFP-CWDM-2 – 1510nm (51) and 1530nm (53) • SFP-CWDM-3 – 1550nm (55) and 1570nm (57) • SFP-CWDM-4 – 1590nm (59) and 1610nm (61) Figure 6. Submodule Identification Arrow indicators 8935CF — Instruction Manual...
  • Page 15 Fiber Optic Cleaning Requirement on page 10. Also visually inspect the LC ferrules for damage or blockage before installing them into the submodule. Figure 7. Installing SMV_SFP on Top of 8935CF Module Duplex end of LC jumper Simplex end of LC jumper 8.
  • Page 16 J2. Note Make sure the Tx3 cable goes to the Ch 3 output LC adapter and the Tx4 cable goes to the Ch 4 LC adapter. Figure 8. Installing SMV_SFP on Bottom of 8935CF Module 8935CF — Instruction Manual...
  • Page 17: Front Module Installation

    8. Replace the front cover for configuring the module using remote controls. Figure 9. Front Module Installation Card Carriers Front Module Side View Locking Pin Card Carriers Module installed Slide top and bottom card carriers on module over top and bottom guides on right of slot. 8935CF — Instruction Manual...
  • Page 18: Cabling

    Installation Cabling Cabling is done on the rear BNCs of the 8935CF-R module illustrated in Figure Note Read the precautions for handling fiber optics before making connections to the fiber optic connectors as described in Fiber Optic Outputs on page Figure 10.
  • Page 19: Electrical Inputs

    Before making any fiber connections, follow the required fiber optic cleaning recommendations given in Fiber Optic Cleaning Requirement on page For the fiber output ports, the 8935CF-R rear module shall follow the channel allocation convention shown in Figure 11. Optical channel 1 and...
  • Page 20 Installation CWDM Configuration The 8935CF module can be used for CWDM (Coarse Wavelength Division Multiplexing) in various configurations in conjunction with 8939FCA modules and 8935FC modules as well as other fiber-ready modules from Grass Valley. The optimum use of CWDM involves the ability to multiplex and demulti-...
  • Page 21 Figure 15 on page 22, two 8935CF (Electrical to Fiber converters) at Location A are used to feed 8 channels of video to an 8939CFA. To utilize this application, one of each of the following four CWDM submodule types must be installed on the two 8935CF modules: •...
  • Page 22 Installation Figure 15. CWDM Configuration 8935CF — Instruction Manual...
  • Page 23: Configuration And Monitoring

    Configuration and Monitoring Configuration and Monitoring 8935CF module configuration and monitoring can be performed locally using the onboard controls or using a web browser GUI interface when the 8900NET Network Interface module is present in the GeckoFlex frame. Control and monitoring is described in the following sections: •...
  • Page 24: Fixed 270M/Mute Mode

    BNC and the fiber optic outputs. Note In this mode only, HD signals will be invalid on the electrical outputs due to an SD slew rate applied to the drivers on the electrical BNCs. 8935CF — Instruction Manual...
  • Page 25: Local Configuration And Monitoring

    Not Monitored. Local Configuration and Monitoring The 8935CF module can be configured and monitored locally (from the front edge of the circuit board) using the rotary and paddle switches and the LEDs mounted on the top and bottom front edge of the module. LEDs are used to indicate status of the signals and the current settings.
  • Page 26: Top Edge Leds

    27. Mode configuration using the front edge controls is described Local Mode Configuration on page Figure 17. Top Edge LEDs and Controls The bi-color (red or yellow) SFP1 and SFP2 LEDs have four states: All Off, Red on, Red blinking, or Yellow on. 8935CF — Instruction Manual...
  • Page 27 A supported SFP submodule is installed in position 2 (bottom of module). Normal operation. SFP2 (bi-color Red flashing An unsupported SFP submodule is installed in position 2 (bottom of module). red/yellow) Red on The SFP submodule in position 2 (bottom of module) has an internal fault. continuously 8935CF — Instruction Manual...
  • Page 28: Bottom Edge Leds

    18. LED color and conditions are described in Table 2 on page 29. Refer also to Table 3 on page 30 for a summary of inter- preting the LED states. Figure 18. Bottom Edge LEDs and Controls PRES AUTO/MUTE 270M/MUTE 1.5G/MUTE AUTO/BYP FIXED/BYP 8935CF — Instruction Manual...
  • Page 29 AUTO/BYP is not the current operating mode selected. AUTO/BYP (yellow) On continuously AUTO/BYP is the current operating mode selected. FIXED/BYP is not the current operating mode selected. FIXED/BYP (yellow) On continuously FIXED/BYP is the current operating mode selected. 8935CF — Instruction Manual...
  • Page 30 Disabled Not Monitored Fixed 1.5G/Mute Not Present Mute Enabled Not Present Disabled Not Monitored Fixed 1.5G/Mute Present Not 1.5Gb/s Mute Enabled Not Present Disabled Not Monitored Reclocked Fixed 1.5G/Mute Present 1.5Gb/s Green Yellow 1.5Gb/s Enabled Present 8935CF — Instruction Manual...
  • Page 31: Local Mode Configuration

    Set Channel 4 operating mode as Auto/Mute, Fixed 270M/Mute, Increment Decrement Fixed 1.5G/Mute, Auto/Bypass, or Fixed Bypass. – – Not used – – Recall factory defaults (all channels have Reporting Enabled and Recall Auto/Mute mode selected). 8935CF — Instruction Manual...
  • Page 32: Remote Monitoring And Controls

    Configuration and Monitoring Remote Monitoring and Controls The 8935CF module can be configured and monitored using the web-based GUI available when an 8900NET module is installed in the GeckoFlex frame. Note The module cannot be controlled with the Newton Control Panel.
  • Page 33 Content display section displays the information page for the selected frame or module (frame slot icons are also active links). Refresh button for manual update of page 8935CF — Instruction Manual...
  • Page 34: Web Page Links

    (page 42), • Slot Config – provides Locate Module and Slot Memory functions along with links to the 8900NET SNMP, LED Reporting, and Frame Alarm configuration web pages (page Figure 20. 8935CF Web Page Links 8935CF — Instruction Manual...
  • Page 35: Status Web Page

    8900NET module. • Rear Module – indicates status of the 8935CF-R module. • Front Processing Module – indicates status of the 8935CF front module. • Fiber Module #1 Top – indicates the status of the SFP fiber optic module installed in Position #1 on the top side of the module.
  • Page 36 Examples of common errors on the Status web page are given in this section beginning with Figure 22 on page Figure 21. 8935CF Status Web Page – No Error Messages Warning message area Optic device signal status and model number 8935CF —...
  • Page 37 Configuration and Monitoring Figure 22 illustrates the Status web page reporting that the top SMV_SFP submodule is not installed. Figure 22. 8935CF Status Web Page – No Top SFP Installed 8935CF — Instruction Manual...
  • Page 38 Figure 23 illustrates the Status web page reporting that the wrong type of SMV_SFP submodule is installed in the top position. The 8935CF will accept only Dual Transmitter fiber optic submodules manufactured by Grass Valley. The correct submodule types are listed under...
  • Page 39 Status web page reporting that the SMV_SFP sub- module installed in the top position is from the wrong manufacturer. The 8935CF will only accept Dual Transmitter fiber optic submodules manufac- tured by Grass Valley. Figure 24. 8935CF Status Web Page – Wrong SFP Manufacturer...
  • Page 40 Status web page reporting that the SMV_SFP sub- module installed in the bottom position is not recognized as the correct type or is reporting an internal error (bad). Figure 25. 8935CF Status Web Page – Unknown SFP Installed 8935CF — Instruction Manual...
  • Page 41 Not Monitored Not Monitored Present Present Present Present Present Present Not Monitored Present Present Present Not Monitored Present Present Present Not Monitored Present Present Present Not Monitored Present Present Present Present Present Present Present Present Present 8935CF — Instruction Manual...
  • Page 42: Settings Web Page

    • Reset Defaults For: – reset the default values for the currently selected channel by selecting the button or for all channels with Current Channel button. All Channels The default values are Input Reporting Enabled and Auto/Mute mode. 8935CF — Instruction Manual...
  • Page 43 The Settings web page shown in Figure 27 illustrates the reporting of an input signal other than 270Mb/s or 1.5Gb/s in Auto/Bypass mode as being Not Monitored. Figure 27. Setting Web Page – Signal Not Monitored 8935CF — Instruction Manual...
  • Page 44: Slot Config Web Page

    • Locate Module this • Slot Identification link • Slot Memory • Frame Health Reporting • LED Reports • SNMP Trap Reports Each of these functions is described in detail below. Figure 28. Slot Config Web Page 8935CF — Instruction Manual...
  • Page 45 Select the Frame Health Reports link to open the 8900NET module Frame Alarm Reporting web page. This web page allows configuration of the alarms and warnings that are reported to the external Frame Health Alarm connector on the rear of the GeckoFlex frame. 8935CF — Instruction Manual...
  • Page 46 8900NET module. This web page allows configura- tion of which alarms and warnings that are reported to the SNMP manage- ment software. Refer to the 8900NET Instruction Manual for complete details on using the 8900NET web pages. 8935CF — Instruction Manual...
  • Page 47: Specifications

    Specifications Specifications Table 6 gives the overall specifications for the 8935CF module. Refer to Table 7 on page 49 for Dual Transmitter SFP detailed specifications. Table 6. 8935CF Specifications Parameter Value Serial Digital Coax Input Connector Input impedance 75 ohm with return loss > 15 dB from 5 MHz to 540 MHz and > 10 dB for 540 MHz to 1.485 GHz...
  • Page 48 Specifications Table 6. 8935CF Specifications Parameter Value Serial Digital Fiber Outputs Grass Valley SMV_SFP SFP-1310-SDTX (1310nm) Dual Transmitter Models Supported SFP-CWDM-1 (1470nm & 1490 nm) (2 frequencies per CWDM device) SFP-CWDM-2 (1510nm & 1530 nm) (see Table 7 on page 49 for submodule SFP-CWDM-3 (1550nm &...
  • Page 49 Maximum distance with SFP-DRX-1 10 km 50 km Minimum distance with SFP-DRX-1 0 km 0 km Maximum distance with SFP-DRX-1 50 km receiver and two 8939CFA units For attenuation requirements, refer to Attenuation Requirements on page 8935CF — Instruction Manual...
  • Page 50: Software Updating

    Software Updating Software Updating Software updating of the 8935CF modules is done using the NetConfig Networking Application PC option. This application is available free of charge from the Grass Valley web site. The procedure for updating software with NetConfig is given in the 8935CF Release Notes when software updates become available.
  • Page 51: Frame Alarm

    • A Status LED icon on each web page to report communication status for the frame slot and acts as a link to the Status page where warnings and faults are displayed (8900NET version 3.0 or later). 8935CF — Instruction Manual...
  • Page 52: Snmp Reporting

    When SNMP Agent software is installed on the 8900NET module, enabled status reports are sent to an SNMP Manager such as the Grass Valley’s NetCentral application. There are both hardware and software report enable switches for each report.
  • Page 53: Service

    If power has been cut off to module, remove the module and replace it in the frame to reset. If the problem persists contact Grass Valley Customer Service.
  • Page 54: Module Repair

    Functional Description Module Repair If the module is still not operating correctly, replace it with a known good spare and return the faulty module to a designated Grass Valley repair depot. Call your Grass Valley Customer Service representative for depot locations.
  • Page 55 Fixed Bypass mode CONFIG LED during configuration overview summary table Frame Health Reporting configuration Frame Status web page using local controls frequently asked questions using remote GUI front module CWDM (Coarse Wavelength Division installation Multiplexing) configuration 8935CF — Instruction Manual...
  • Page 56 Slot Config web page Locate Module function slot memory SMV_SFP submodules installation kit assembly module health status list of models used on 8935CF module repair SFP-DRX-1 Dual Receiver for 8935FC Module Status page specifications types used on 8935CF warning messages...
  • Page 57 Status web page troubleshooting video inputs coax video outputs coax voltage test points warning messages on Status web page web browser interface links overview web site documentation FAQ database Grass Valley software download 8935CF — Instruction Manual...
  • Page 58 Index 8935CF — Instruction Manual...